Final Check and Trial Operation

To complete the installation, perform the following checks and tests to
ensure that the air conditioner operates correctly.
Check the followings:
• Strength of the installation site
• Tightness of pipe connection to detect gas leak
• Electric wiring connection
• Heat-resistant insulation of the pipe
• Drainage
• Grounding conductor connection
• Correct operation (follow the steps below)
1. Press the Power
The indicator on the indoor unit lights up.
2. Press the Mode button to select Cool or Heat mode.
In Cool mode, use Temp + or - button and set the temperature at 16 °C.
In Heat mode, use Temp + or - button and set the temperature at 30 °C.
• Approximately 3~5 minutes later, outdoor unit will start to operate and the Cool or Warm air will blow out.
• After 12 minutes of stationary condition check the indoor unit air treatment:
Cooling mode (indoor unit check)->
Heating mode (indoor unit check)
3. Press the Air swing
4. Press the Power
• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe
place.

Pump down procedure (when removing the product)

1. Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes.
2 . Release the valve caps on High and Low pressure side.
3 . Use L wrench to close the valve on the high pressure side.
4 . Approximately 2 minutes after, close the valve on the low pressure side.
5 . Stop operation of the air conditioner.
6 . Disconnect the pipes.
MAX_XSA_IBIM_DB98-33747A_E.pdf
button and check the following:
Inlet air temp. - Outlet air temp : From 10 °C to 12 °C ( indicative delta T)
->
Outlet air temp. - Inlet air temp : From 11 °C to 14 °C (indicative delta T)
button and check the following:
button to stop the operation.
conditioned space.