Page 1
SPLIT-TYPE AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT Basic Code : Model Code : AIR CONDITIONER CONTENTS 1.Precautions 2. Product ations 3. Alignment and Adjustments 4. Disassembly and Reassembly 5. Assy Control 6. Electrical Parts List 7. Wiring Diagram 8. PCB Diagram 9.
Never store or load the air conditioner upside down or sideways to prevent the da age to the co pressor. Young children or infir persons should be always supervised when they use the air conditioner. Ma current is easured according to IEC standard for safety. Current is easured according to ISO standard for energy efficiency. Samsung Electronics...
On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. Beat the heat with your own air conditioner this summer. Your new air conditioner not only provides maximum cooling power in the summer, but also can be an running cost.
880*260*360 880*260*360 Outer Dimension Outdoor Unit 926*640*384 926*640*384 Indoor Unit 44/42(Sound Pressure)/56(Sound Power) 46/44(Sound Pressure)/58(Sound Power) Noise Outdoor Unit 51(Sound Pressure)/59(Sound Power) 53(Sound Pressure)/62(Sound Power) Air Purifying System Filter FULL HDFILTER FULL HDFILTER 2- 6 Samsung Ele ctr onic s...
Page 12
DESCRIPTION Power Off Reset Normal Operation Abnormal Communication IPM Over Current(O.C) Comp Starting Error Heatsink Sensor Error Heatsink Over Heat DC-Link Voltage Under/Over Error Over Voltage Protection Error OLP Over Heat OLP Sensor Error Current Sensor Error Input Current Sensor Error Comp Vlimit Error Comp Current Limit Error 1min.
FRONT.(use + Screw Driver) 4) Loosen connector wire(white) and detach the temperature sensor wire. 5) To detach the FRONT-PANEL the main frame, unfasten 2 screw at the bottom.(use + Screw Driver) 6) Take off the FRONT-PANEL,lifting up the bottom. Samsung Electronics...
Page 18
TRAY-DRAIN towards you. CONTROL IN 1) Unfasten the earth screw.(use + Screw Driver) 2) Detach COVER-CONTROL from the CASECONTROL. 3) Detach the temperature sensor. 4) Loosen MOTOR Wire. 5) Take off the CASE-CONTROL from the main frame. Samsung Electronics...
Page 19
Parts Procedure Remark 1) Unfasten the screw. 2) Cut the cable tie. 3) Loosen the terminal block wires. Caution: The terminal is locking type. So, when you separate terminals, pull pressing the button. Button Samsung Electronics...
Page 20
• • 7) Loosen the display wire connector Caution: When you separate the connector, pull pressing the locking button. 8) Loosen the sensor wire connector(CNS43), the earth wire connector(CNP73).T/B fuse wire connector(CNS11),communicition wire connector(CNS22) Samsung Electronics...
Page 21
1) Unfasten the screw at the right side. (use + Screw Driver) 2) Unfasten the screw at the left side. (use + Screw Driver) 3) Detach the HOLDER PIPE. 4) Take off the EVAPORATOR from the main frame. Samsung Electronics...
Page 22
2) unfasten the 3 points screws in the CASE- CONTROL, and then detach the CASE. (use + Screw Driver) 3) unfasten the screw a little.(use + Screw Driver) 4) Lift up the evaporator slightly and pull the CROSS-FAN to the left side. Samsung Electronics...
4-2. Outdoor Unit Procedure Parts Remark Common Work 1) Loosen each screws and detach the Cabi Top Cover 2) L oosen screws of the C abi Front and detach it . Samsung...
Page 24
Remark 3) Remove the 4 Cond Bar from the holder of outdoor unit cabinet. 4) Loosen fixing screws from the Cabi Front Lh and detach it. 5) Loosen fixing screws from the Cabi Side Rh and detach it. Samsung Electronics...
Page 25
(Use Monkey Spanner.) 2) Detach the Fan Propeller. 3) Loosen 4 fixing screws to detach the Motor. (Use Monkey Spanner.) 4) Disconnect the wire between Ass’y Control Out and Motor. 8) Loosen 2 fixing bolts and detach the Bracket Motor Samsung Electronics...
Page 26
3) Detach several connectors from the PCB of Ass’y Control Out. Heat Exchanger 1) Release the refrigerant at first. 2) Loosen fixing screw on both sides. 3) Disassemble the pipes in both inlet and outlet with welding torch. 4) Detach the Heat Exchanger. Samsung Electronics...
Page 27
Parts Procedure Remark Compressor 1) Loosen the fixing nut and detach the Compressor Lead Wire. (Use Monkey Spanner.) 2) Loosen the bolts at the bottom of Compressor like the picture on the right side. (Use Monkey Spanner.) Samsung Electronics...
1 PC ASSY CONNECTOR WIRE-DC SIGNAL DB93-14276A 1 PC ASSY CONNECTOR WIRE-DC SIGNAL DB93-14277A 0 PC DB93-14277B 1 PC ASSY CONNECTOR WIRE-DC SIGNAL DB93-14278A 0 PC ASSY CONNECTOR WIRE DB93-15008A 1 PC ASSY PCB SUB-HEATER DB93-13220A 1 PC Samsung Electronics...
If not, there exists a possibility of fire which can be caused by electric heat in the connecting part. : Good Bad : Ring terminal is connected reversely Bad : Not clamped Screw Bad : In the gap between Ring terminal & Screw Bad : Unused Ring Terminal Samsung Electronics...
9-1-1 Main parts Room temperature sensor Air intake (up and down) Blade pin lever Display Timer/ indicator Operation indicator Power button Remote controller receiver...
Vertical air swing blade movement automatically Power Mode Set one of the 5 operating modes conditioner Temp + Increase/Decrease the Adjust the fan speed temperature by 1 ˚C. Options Horizontal air swing Select options during operation blades movement automatically Timer Select Timer option Settings Select settings...
10-1 Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION power The air Check status and then operate the air conditioner conditioner does again. not work at all. Plug in or switch on the circuit breaker and then operate the air conditioner again.
Page 56
Heat the outdoor unit. mode in winter. Water is dropping Water may be generated because of the temperature from the outdoor unit piping connection. Samsung Electronics...
Is the connec on of power cable Correct the wrong cable. and communica on cable normal? Exchange the indoor unit PBA. Is the communica on error Terminate the service. occurred again? Exchange the outdoor unit PBA. 10-2 Samsung Electronics...
Page 58
Detach the assembled sensor from the PBA sensor connector and measure the sensor resistance with ohmmeter(tester) Sensor Replace Sensor resistance value : 20 - 12.09kohm Is the sensor resistance value #1 - #2 30 - 8.31kohm 10kohm 3% at the room temperature 35 - 6.94kohm of 25...
Page 59
Detach the assembled sensor from the PBA sensor connector and measure the sensor resistance with ohmmeter(tester) Sensor Replace Sensor resistance value : 20 - 12.09kohm Is the sensor resistance value #3-#4 30 - 8.31kohm and #5-#6 10kohm 3% at the room temprature 35 - 6.94kohm of 25 40 - 5.83kohm...
Page 60
Unplug the power cord and plug it a er 30seconds later. Check the as in the procedure. Is the lamp blinking? No power. Is the connected louver wire? Connect the wire PBA to louver motor Does opera on start when swing Normal bu on of the remote control unit pushed?
Page 62
Indoor fan motor speed detecting error(BLDC MOTOR)
Page 63
Is the sensor connector(CN251) Reconnect the sensor connector. connected correctly in accordance with a color(WHT,2PIN)? Sensor Replace Sensor resistance value : 20 - 242kohm Is the sensor resistance value #3-#4 30 - 166ohm 200kohm±3% at the room temperature 35 - 138ohm of 25 40 - 115kohm Connect the sensor to PBA connector (2piin)
Page 64
Restart a er power off. Is the restart error occurred again? Terminate the service Is the connec on of compressor Connect the comp wire normally wire is normal? Download the EEPROM data Terminate the service Is the restart error occurred again? Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated?
Page 65
Restart a er power off. Is the restart error occurred again? Terminate the service Is the connec on of compressor wire is normal? (PBA and Connect the comp wire normally Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated?
Page 66
Restart a er power off. Is the O.C error occurred? Terminate the service Is the connec on of compressor Connect the comp wire normally wire is normal? Is the O.C error occurred again? Terminate the service Is the condi on of indoor/outdoor Restart a er returning to the normal load temperature normal load? Is the O.C error...
Page 67
Is the connected of reactor wire? Connect the reactor wire (PBA-Reactor) Restart a er power off. Start the opera on (cooling mode or hea ng mode) Is the DC_link voltage (CE101) is Check the power input normal in opera on mode? Normal range(280Vdc~320Vdc) Is the DC_link sensing voltage(R104) Exchange the Outdoor PBA...
Page 68
Is the connected of reactor wire? Connect the reactor wire (PBA-Reactor) Restart a er power off. Is the the input voltage is nomal? Check the input power in the powercord. Normal range(180Vac ~ 270Vac) Restart a er power off. Start the opera on (cooling mode or hea ng mode) Is the DC_link voltage (CE101) is normal in opera on mode? Check the input power...
Page 69
Restart a er power off. Is the condi on of indoor/outdoor Restart a er returning to the normal load temperature normal load? Is the I_trip error Terminate the occurred again? service Is the posi on of temperature Correct the sensor posi on or exchange the sensor sensor and the sensing value normal? Is the connec on cable for the...
Page 70
Restart a er power off. Is the PFC shunt and IPM shunt Exchange the Outdoor PBA resistance value correct? Is the current sensor error Terminate the service appeared again? Exchange the Outdoor PBA 10-1...
Page 71
Restart a er power off. Are there screws in PBA-heatsink? Fastening the screw (4 screws) Check the fan connec on Is the fan opera on normal? Change the Fan motor Exchange the Outdoor PBA 10-1 6...
Page 72
Restart a er power off. Is the O.C error occurred? Terminate the service Is the connec on of compressor Connect the comp wire normally wire is normal? Is the O.C error occurred again? Terminate the service Is the condi on of indoor/outdoor Restart a er returning to the normal load temperature normal load? Is the O.C error...
Page 73
power off and download EEPROM data (or. Insert the service EEPROM IC) Restart a er power off Terminate the service Is the error appeared again? Exchange the Outdoor PBA 10-1...
Page 74
Restart a er power off Is the AC line zero cross signal error Terminate the service appeared again? Exchange the Outdoor PBA 10-1...
Page 75
Unplug the power cord Is the power cord connected normal? Terminal block : 1(L) -2(N) Reconnect the power cord correctly. PBA:CN71: #1-#3 Check the fuse open or not? Exchange the PBA (F701,F702) Restart a er power off. Check the power source. Is the power normal? The remote control signal receiver on the display Press the power bu on on the...
Page 76
Unplug the power cord Is the power cord connected normal? Is the cable connected correctly Reconnect the power cord correctly. between indoor and outdoor unit? Is the wiring correctly from outdoor terminal block to PBA Check the fuse open or not Exchange the outdoor PBA (F001) Restart a er power off.
Page 77
Restart a er power off. Are there screws in PBA-heatsink? Fastening the screw (4 screws) Check the fan connec on Is the fan opera on normal? Change the Fan motor Exchange the Outdoor PBA 10-22...
Item Reference 3TH 4TH ITEM Item Item Export 12Year INVERTER HP Export 13Year INVERTER CO Export 14Year Export 15Year Export 16Year 9TH DIGIT Item1 Export 1st MODEL A Export The virus doctor (The India / Latin America A / PAC K besides) S Export Export NO virus doctor (the India / Latin America A / PAC K besides) Export 3rd MODEL C...
Note : Please measure the refrigerant pressure after the air conditioner operates on testing cooling mode during more than 10 minutes. Indoor Temp. Variation : 20°C ~ 32°C Outdoor Temp. Variation : -5°C ~ 45°C Low Refrigerant Pressure Distribution * * Samsung Electronics 12-2...
Opening the panel Tightly grab top of the front panel and pull it down to open. Then slightly lift the panel up. and slide it down. Open the panel and put the Air filter out. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water.
Page 94
12-7-3 POWER SUPPLY Working Voltage 176V ~ 264V Within a 3% Deviation from Each Voltage at the Main Terminal of Voltage Imbalance Outdoor Unit Starting Voltage Higher than 80% of the Rated Voltage 12-7-4 WORKING RANGE Applicable models: AR09JSFPPWQN(X)EE AR12JSFPPWQN(X)EE working range min ( max (...