Download Print this page

Hitachi CP-WU9100 User Manual page 13

Hide thumbs Also See for CP-WU9100:

Advertisement

Communication settings
1. Protocol
19200bps, 8N1
2. Command format
Byte Number
Command
Action
<SET>Change setting to
desired value [(cL)(cH)]
by [(bL)(bH)].
<GET>Read projector
internal setup value [(bL)
(bH)] .
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
<EXECUTE> Run a
command [(bL)(bH)].
[Header code] [Packet] [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 to 4.
[CRC flag]
For byte number 5 and 6, refer to
command table
[Action]
Set functional code to byte number 7 and 8.
<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> = [04h, 00h]
<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]
Refer to the Communication command table
[Type] [Setting code]
For byte number 9 to 12, refer to
command table
(h shows hexadecimal)
0
1
2
Header
code
Packet
L
H
BEh EFh
03h
(&21).
(&21).
3
4
5
Header
Data
CRC
size
flag
L
H
L
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
06h 00h
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
RS-232C Communication / Network
(&above).
RS-232C Communication / Network
RS-232C Communication
7
8
9
10
6
Data
Action
Type
H
L
H
L
H
11
12
Setting
code
L
H
13

Advertisement

loading

This manual is also suitable for:

Cp-hd9950