Connect Flow Sensor To Hot & Cold Supply Of Shower; Control Unit; Control Unit Location - Whale SDP073R Installation Instructions Manual

Model number sdp073r dry deck 20
Table of Contents

Advertisement

8
Connect Flow Sensor to Hot
and Cold Supply of Shower
1.7
Fit the Flow Sensors with the arrow in the
direction of flow to the shower, downstream
of any other connections to the water supply.
Each sensor must be protected by a filter
which is supplied in the kit.
The flow sensors must be mounted in a
straight length of unstressed pipe.
Note: Do not remove, tighten, tamper with this
device, failure to do so will invalidate warranty.

Control Unit

1.8
Location of Control Unit:
Locate the control unit outside the showering
area (as per BS7671: 2001 in zone 2 or 3,
refer to the drawing).
The control unit meets IP45.
Tighten all cable entry grommets, even
unused ones, to seal the Control Unit.
Connect Control Unit to 240V a.c. supply via
an unswitched 5 amp fused spur.
1.8
C
1.9
1.10
Zone 0
Zone 2
0.6 m
Zone 1
Bathroom zones (BS7671: 2001)
Zone 3
2.4 m

Advertisement

Table of Contents
loading

Table of Contents