Dry-Deck 20 Status Information
The Dry-Deck 20 stores information on the
software version and on the usage of the pump.
This information may be accessed by pressing the
up arrow while not in any Set Up mode.
The fields are displayed on the 7-segment LEDs as
follows:
00
- Not currently used
14
- Software version / software revision
ER
- (field separator) 'Error'
01
- Error code (Object location)
02
- Error code (Object ID)
PP
- (field separator) 'Pump Powered' time
01
- Hours powered 100,000's, 10,000's
02
- Hours powered 1000's, 100's
07
- Hours powered 10's, 1's
22
- Minutes powered 0 - 60
PO
- (field separator) 'Pump On' time
02
- Hours pumping 1000's,100's
07
- Hours pumping 10's, 1's
22
- Minutes pumping 0-60
PC
- (field separator) 'Pump Cycles'
12
- Pump cycles (1000's, 100's)
10
- Pump cycles (10's, 1's)
--
- (field separator)
returns to normal display
Status display mode will be exited if the keys are
inactive for a period greater than 10 minutes
(same as configuration mode).
Status display will be exited if either the mode or
decrement key is pressed.
Status display will be exited when all the fields
have been scrolled through.
Last Error Code
Two bytes representing the last recorded is
automatically erased after it has been viewed once.
Duration Powered
This is a record for the length of time the system
has had power applied to it. It consists of hours
and minutes (see opposite).
Total Pump Run Time
This is a record for the length of time the pump has
been running. It consists of hours and minutes
(see opposite).
Total Pump Cycles
This is the total number of times the pump has
been activated (0-9999).
Currently this is set to increment every time the
pump is turned on following an off state so a purge
cycle will also trigger the count. (The software
could discriminate if required).