Worcester Greenstar Heatslave II 12/18 Installation, Commissioning & Servicing Instructions page 36

Floor standing oil fired condensing combination boiler balanced flue
Table of Contents

Advertisement

Service and Spares
Nominal boiler rating at normal operating temperature using Kerosene (Class C2)
Oil pump pressure
Nozzle
bar
psi
Greenstar Heatslave II 12/18 model
0.35 x 80° SR
9.0
132
0.45 x 60° ES
7.5
110
0.55 x 80° ES
7.8
115
Greenstar Heatslave II 18/25 model
0.50 x 80° ES
8.5
125
0.60 x 60° ES
8.5
125
0.75 x 80° ES
7.5
110
Greenstar Heatslave II 25/32 model
0.75 x 80° ES
7.5
110
0.75 x 80° ES
10.0
147
0.85 x 80° EH
9.5
140
Table 9 Combustion settings
36
Approximate
flue gas
Fuel flow rate
temperature
Kg/h
l/h
°C
1.04
1.32
72
1.28
1.63
77
1.54
1.96
80
1.58
1.96
76
1.84
2.33
81
2.15
2.72
87
2.15
2.72
79
2.46
3.12
81
2.78
3.52
86
Approximate
Input
air setting
(appliance)
%CO2
kW
11.0
3.0
12.4
11.5
5.0
15.4
12.0
5.0
18.5
11.5
3.0
18.5
12.0
3.5
22.1
12.0
4.5
25.7
11.5
3.5
25.7
12.0
4.5
29.4
12.5
5.0
33.0
Greenstar Heatslave II External
Output
Air damper
(appliance)
disk setting
Burner head
kW
12.0
12/15
LD2X Short
15
12/15
LD2X Short
18.0
18
LD2X Short
18.0
18
LD2SX Short
21.5
21.5
LD2SX Short
25.0
25
LD2SX Short
25.0
N/A
T2 Short
28.5
N/A
T2 Short
32.0
N/A
T2 Short
ErP -
6 720 813 345 (2014/09)

Hide quick links:

Advertisement

Table of Contents
loading