Installing the Avaya Ethernet Routing Switch
• Do not remove the wrist or ankle strap until the installation is complete.
Preventing electrostatic damage in new cable installations
With new cable installations, Avaya recommends that you use an ESD discharge cable to reduce
the potential for damage from static, that can build up in cables. The following figure illustrates an
ESD cable.
Figure 1: Job aid
To install the ESD discharge cable, perform this procedure.
1. Connect the ground lug on the ESD discharge cable to a safe and suitable earth ground.
2. Connect all RJ-45 cable connectors to the female RJ-45 connector of the ESD discharge
cable for at least 5 seconds, and then connect each RJ-45 cable connector to the switch.
3. Leave cables connected to the networking equipment. After you connect cables to
networking equipment, the cables do not build up charge.

Environmental requirements

The following table provides the environmental requirements for the individual switches. Ensure that
the area where you install the switch and where it operates meets these requirements.
Table 2: Environmental requirements
Environmental requirement
Ambient Temperature
August 2016
Values
0°C to 50°C, continuous operation
Installing Avaya ERS 4800 Series
Comments on this document? infodev@avaya.com
Table continues...