• When all the zones have been programmed, simply press enter to return to
program mode.
3.8 Programming Passwords
The keypad can be used to program user passwords (Default: 1234) and the Master
password (Default: 123456):
Programming User Passwords:
1. Switch the E12 to Off Mode.
2. Enter the 6 digit master code, press the program button followed by enter. The
program button will light up, showing that the E12 is ready to be programmed.
3. Press the MEM button followed by the user number (1-12). Pressing 2, for
example, will mean that user password 2 must be programmed in. The selected
number button will start to flash.
4. Enter the 4 digit numeric password and press enter.
5. To program the next password start from step 3 above. All 12 user passwords
are programmed in the same way.
Programming the Master Password:
1. Switch the E12 to Off Mode.
2. Enter the 6 digit master code, press the program button followed by enter. The
program button will light up, showing that the E12 is ready to be programmed.
3. Press the MEM button followed, by 2
button will start to flash.
4. Enter the 6 digit numeric password and press enter.
5. Press enter a second time to exit program mode.
nd