3. Press the Panic button on the sensor and hold for 3 sec.
4. The Control Panel Learn LED may switch off.
5. The Control Panel Learn LED should flash and then stop.
6. To program this device to zone follow the steps in section 3.2 of this document.
3.1.6. High power door guard
1. Open up the device and check that LK2 is configured correctly.
Check that the battery is connected.
2. Reassemble the unit and Press the Panic Button. Check that the LED of the sensor
comes on and stays on for 2 to 3 seconds after you release the button.
3. Press the learn button on the panel once and make sure the LED switches on and
stays on.
4. Press the Panic button on the sensor and hold for 3 sec.
5. The Control Panel Learn LED may switch off.
6. The Control Panel Learn LED should flash and then stop.
7. To program this device to a zone follow the steps in section 3.2 of this document.
LK2:
• Connected for
E6 panels.
• Unconnected
for
E12
and
E45 panels.
Dipswitch
Panic Button
(Back of board)
Battery connector