The E12 can be programmed to switch to AWAY Mode at a specific time of day every
day. This is very useful for Commercial applications where the E12 will arm at, for
example, 18:00 every night. The E12 also has a built in calendar, enabling the timer to
take into account weekends but NOT holidays. No activation or deactivation will take
place on weekends by the system timer these will have to be manual.
Both partitions (See section 1.4) can be armed and disarmed separately by the system
timer at different times.
When the E12 Armes, it will respond with 1 beep on the internal siren, the away button
will light up and a security system armed SMS will be sent. In the SMS By "System
Timer" is displayed when the E12 is armed by this timer.
1.3.2. GAS discharge activation option:
The GAS discharge will be triggered every time the alarm is activated by a sensor or by
means of a remote control or cellular phone.
The activation of GAS is counted and timed and a low GAS warning will be sent when
the GAS canister needs to be replaced.
GAS will be triggered Depending if the GAS is enabled or not. This is done with the
following messages: $XXXXG1 = GAS enabled, $XXXXG0 = GAS disabled
GAS can be manually triggered by using $XXXXG9 at any time.
When the gas is triggered, the E12 will deliver a 4 sec spray, which will fill a room of 200
square meters practically instantaneously. A total of 8 bursts of this length can be
delivered per canister.
After the doors and windows have been opened, it will take approximately two and a
half hours for the gas to dissipate out of the house.
Warning: The gas is hazardous to any living creature. Don't enable the gas discharge
option if pets are left in the house while occupants are away from the premises.
1.3.3. Supervision function:
All sensors are supervised by the E12 and should a sensor fail to report to the E12, a
supervision failure SMS will be sent.
1.3.4. "Power Supply Battery low" warning function:
A Battery low SMS message will be sent every time the power supply battery voltage
drops below a 10.7V. When the battery is charged after the Battery low SMS was sent,
a Battery OK SMS will be sent only when the battery voltage stays above 10.7V for 60
minutes.
On power up, a Battery OK message will be sent if the battery voltage is above the
predetermined value.
1.3.5. "Sensor Low Battery" warning function: