Jackson 24P-NSU Service Manual page 7

Table of Contents

Advertisement

The steam equalizing vent is located on the back upper left corner of the
dishmachine.
The vent should not be blocked or prevented from venting steam
off from inside of unit.
are not excluded from this requirement.
REFER TO FIGURE 2
STEPS :
1. Install 1-1/4 inch pipe to equalizing vent fitting and connect to
appropriate venting system. NOTE: Do not pipe steam line downward
toward floor, this will restrict venting of steam.
WARNING:
All
field
electrical codes.
Install proper circuit breaker, wire and conduit size.
MACHINE DATA PLATE is located at top of inner door.
REFER TO FIGURE 2
STEPS :
1.
Remove control box side panel and lay aside.
2.
Make
electrical
box and connect 440 VOLT, 60 HZ, 3 PHASE service to terminal block marked
LI, L2 and L3.
CAUTION:
GROUNDED.
WARNING:
INSTALLATION INSTRUCTIONS
STEAM EQUALIZING VENT
Under-counter machines installed inside of cabinet
ELECTRICAL POWER CONNECTION
wiring
connections
connection
Connect GROUND WIRE to grounding lug provided.
INJURY OR DEATH MAY OCCUR FROM SHOCK IF MACHINE IS NOT PROPERLY
DO NOT CONNECT WILD/HOT LEG OF 3 PHASE POWER TO LI OR L2 .
TO GROUND FOR PROPER VOLTAGES.
[ PAGE 4 ]
must
conform
to
the
through
conduit
hole provided at rear of
Local
and
National
CHECK LEGS