Download Print this page
Viking pump 56M Technical & Service Manual

Viking pump 56M Technical & Service Manual

Series 56 and 456

Advertisement

Quick Links

Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com
CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . 1
Special Information . . . . . . . . . . . . . . . . . . . 1
Pressure Relief Valves . . . . . . . . . . . . . . . . . 2
Maintenance . . . . . . . . . . . . . . . . . . . . . . 2
Disassembly . . . . . . . . . . . . . . . . . . . . . . 2
Installing Casing Bushing . . . . . . . . . . . . . . . . 4
Assembly . . . . . . . . . . . . . . . . . . . . . . . . 4
Pressure Adjustment . . . . . . . . . . . . . . . . . . 5
Special Pump Designs . . . . . . . . . . . . . . . . . 5
INTRODUCTION
The illustrations used in this maintenance bulletin are for
identification purposes only and should not be used for
ordering parts. Secure a parts list from the factory or a
Viking representative. Always give complete name of part,
part number and material with the model and serial number
of the pump when ordering repair parts.
UNMOUNTED PUMP
PACKED MECH. SEAL
C56
C456
F56
F456
FH56
FH456
This manual deals exclusively with Pump Models C, F,
FH56M and C, F, FH456M General Purpose Pumps. Refer
to Figures 1, 2, 4, and 7 for general configuration and
nomenclature used in this bulletin.
All pumps can be furnished with either a mechanical seal or
packing. Packed pumps are furnished with suitable packing
for the liquid pumped. A seal pump can be changed to a
packed pump by removing the mechanical seal and inserting
the packing spring, inner packing gland, packing and outer
packing gland. The mechanical seal pump is dimensionally
interchangeable with the packed pump.
NOTE: SERIES 56 PACKED PUMPS DISCONTINUED AS OF 1Q16.
VIKING PUMP, INC.
TECHNICAL SERVICE MANUAL
GENERAL PURPOSE HUB MOUNTED PUMPS
UNITS
Units are designated by the
unmounted
pump
model
numbers followed by a letter
indicating drive style.
M = Motor Mounted Unit
A Unit of IDEX Corporation
SERIES 56 AND 456
SIZES C - F - FH
SERIES 56M AND 456M PUMP
(3 GPM Size Shown)
Packed Or Mechanical Seal Type.
Valve On Casing - Clockwise Rotation
SPECIAL INFORMATION
DANGER !
Before opening any Viking pump liquid
chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.)
Be sure:
1. That any pressure in the chamber has
been completely vented through the
suction or discharge lines or other
appropriate openings or connections.
2. That the driving means (motor,
turbine, engine, etc.) has been "locked
out" or made non-operational so that
it cannot be started while work is
being done on pump.
3. That you know what liquid the
pump has been handling and the
precautions necessary to safely
handle the liquid. Obtain a material
safety data sheet (MSDS) for the
liquid to be sure these precautions
are understood.
Failure
to
follow
precautionary measures may result in
serious injury or death.
Cedar Falls, IA 50613 USA
SECTION
TSM 320.1
PAGE
1 OF 7
ISSUE
F
FIGURE 1
above
listed

Advertisement

loading

Summary of Contents for Viking pump 56M

  • Page 1 Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL SECTION TSM 320.1 GENERAL PURPOSE HUB MOUNTED PUMPS PAGE 1 OF 7 SERIES 56 AND 456 ISSUE SIZES C - F - FH CONTENTS Introduction .
  • Page 2: Safety Information And Instructions

    ● You know what material the pump has been For weight of the pump alone (which does not include handling, have obtained a material safety data the drive and/or base plate) refer to the Viking Pump sheet (MSDS) for the material, and understand product catalog.
  • Page 3: Special Information

    Pressure relief valves should not be used to control DANGER ! pump flow or regulate discharge pressure. For additional information on pressure relief valves, Refer Before opening any Viking pump liquid to Technical Service Manual TSM000 and Engineering chamber (pumping chamber, reservoir, Service Bulletin ESB-31.
  • Page 4 FIGURE 2 EXPLODED VIEW SERIES 56 AND 456 ITEM NAME OF PART ITEM NAME OF PART ITEM NAME OF PART Electric Motor Inner Packing Gland (Series 56 only) Rotor and Shaft Assembly Motor Shaft Pin Packing Spring (Series 56 only) Idler Coupling with Setscrew Casing...
  • Page 5 SPRING WASHER ROTARY MEMBER PACKING NUT SPRING SEAL SEAT FIGURE 5 RETAINER LUG CARBON WEAR RING INSTALLING CASING BUSHING ASSEMBLY The casing bushing can be replaced in the following manner: Clean all parts thoroughly. Insert a bar approximately 0.94” diameter and at least 3.5” Place the rotor and shaft in the casing.
  • Page 6: Pressure Adjustment

    Failure to properly mount guards may desired. result in serious injury or death. PRESSURE ADJUSTMENT DANGER ! Before opening any Viking pump liquid chamber (pumping chamber, reservoir, relief valve adjusting cap fitting, etc.) Be sure: 1. That any pressure in the chamber has...
  • Page 7 WARRANTIES ARE EXPRESSLY EXCLUDED. See complete warranty at www.vikingpump.com. NOTE: SERIES 56 PACKED PUMPS DISCONTINUED AS OF 1Q16. • • © 3/2016 Viking Pump Inc. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA 50613 USA All rights reserved...

This manual is also suitable for:

Fh56m456mFh456mF56mF456m