  • Page 1 Operator’s Guide VP330 Chamber Machine Commercial Vacuum Packaging System...
  • Page 2: Limited Warranty

    Kansas City, MO 64141 800.821.7849 ™ , ® , ® , ™ All Rights reserved. GameMaster VacMaster VacStrip Total Freshness System and Commercial Culinary Concepts are trademarks or registered trademarks of ARY, Inc. in the United States and other countries. Patent #5,239,808...
  • Page 3 ® VP330 is designed as a commercial grade vacuum packaging system and can be used for a wide variety of products. With the VP330 you can extend food life, maintain food quality, reduce freezer burn and reduce food waste and costs.
  • Page 4: Model

    Read and complete the following to prevent any damage. Oil must be added to the vacuum pump before using. VacMaster model VP330 uses an oil vacuum pump. ® For shipping purposes there is no oil in the pump. Oil must be added.
  • Page 5: Packaging Information

    Packaging Information With the VP330, you can easily package a wide variety of sizes and shapes. You can also prep and store smaller individual serving portions as well as bulk items. • Keeps food fresh 3-5 times longer than conventional storage bags.
  • Page 6 Fig. 2 Model 330 Figure 2 Part Assembly Number Name Quantity number Part Number Housing Case Cable Sheath Vacuum Gauge 979126 Instrument Panel 979125 979334 Selector Switch Circuit Board 979127 Power Switch Bracket 979137 Power Switch 979138 Combined Solenoid Valve 979360 Sealing Transformer 979341...
  • Page 7 Fig. 1 Part Assembly Name Quantity Number Part Number 1 Chamber Lid 979331 2 Upper Platen for Lid 3 Lower Platen for Lid 4 Lid Gasket 979202 5 Left Hinge 6 Hinge Support 7 Proximity Switch Support 979354 8 Proximity Switch 979355 9 Stay Bar 10 Right Hinge...
  • Page 8 Neglecting these basic guidelines can result in food spoilage, and in some cases, illness or death. Once you familiarize yourself with the VP330 and the procedures, you will feel at ease using the VacMaster Chamber Machine and enjoy a higher ®...
  • Page 9: Safety Precautions

    ▪ Read Operator’s Guide carefully before using the machine for the first time. ▪ Do not use the VP330 on wet or hot surfaces, or near a heat source. ▪ Do not immerse machine or power cord in water or any other liquid.
  • Page 10: Care, Maintenance & Troubleshooting

    Care, Maintenance & Troubleshooting The VacMaster machines have been designed with ease of use and low ® maintenance in mind. Follow these few points for years of trouble-free operation: Cleaning ◦ UNPLUG your Chamber Machine before cleaning. ◦ Regularly clean machine with damp cloth removing any food debris.
  • Page 11: Vacuum Pump Maintenance

    Oil Fill Oil Drain Bolt Vacuum Pump Maintenance The VP330 vacuum pump requires periodic oil changes. Required oil change schedule: ◦ First oil change: after 25 hours of VP330 usage. ◦ Future oil changes: change oil after every 60 hours of machine usage.
  • Page 12: Vacuum Chamber

    Features of VP330 Seal Bars *Filler Plates Silicone Bars *Lid Lock Sealing Option Switch Power Switch Control Panel *Lid Lock *Lid Lock Feature: not to be used during the vacuuming cycle. Used to keep lid closed not to be used during the vacuuming cycle. Used to keep lid closed when machine is not in use or while machine is in storage.
  • Page 13: Operating Instructions

    Operating Instructions 1. Select the Pouch Select the proper size VacMaster barrier vacuum pouch. Allow a minimum of 1” to 2” of extra headspace at the top of the pouch to ensure a quality, positive seal. 2. Plug in machine and switch power “ON”...
  • Page 14: Seal Bar.

    5. Fill pouch and place in Chamber ◦ Remove or replace filler plate to accommodate the product to be vacuumed. ◦ Always use as many filler plates as possible. Lay the pouch flat in the chamber with the opening of the pouch across the seal bar. ◦...