INSTALATION OF DIFFUSER AND INLET GRILLE

MOUNTING THE DIFFUSER PANEL TO THE UNIT
Check that the position in which the diffuser is mounted is the right one.
1. - Release the air intake grille.
2. - The diffuser panel can then be provisionally positioned on the cassette using the fixing clips.
3. - The diffuser is fastened with the eight bolts supplied.
4. - Make sure that the frame has not been deformed in the installation, by an excessive tighten of the bolts. There
must be no recirculation of air between intake and outlet air paths.
The diffuser panel is sealed with insulation to avoid air
gaps between the unit and the air panel. The insulation
can be compressed from 8 mm to 3 mm, allowing the panel
to be tightened to the cassette by up to 5 mm.
WARNING
Electric shock hazard can cause injury or death. Before
attempting to perform any service or maintenance on the
unit, turn OFF the electrical power, and check that the fan
has stopped.
Insulation
INSTALLATION OF DISPLAY UNIT HOLDER
The display holder includes the infrared receiver (when the remote controller is of this type) and indicators.
(Refer to the corresponding infrared controller manual)
The infrared receiver panel is connected to the electrical board by means of wires.
1. - The display unit holder is mounted by two screws, on any side of the diffuser panel (Fig 1).
2. - The swing motor should now be connected with the power supply wires (it depends on versions).
MOUNTING THE AIR INTAKE GRILLE AND FILTER ASSEMBLY
The position in which the grill is mounted depends on the position of the display unit holder.
1.- The grill fixing hooks should be fitted into the holes provided.
2.- The stays need to be placed between the diffuser and the inlet grille (Fig 2).
3.- The grille is mounted on the diffuser via two hand triggers. Initially pull off the hand triggers, then insert the grille
into the diffuser and release the hand triggers. When this operation is completed the grille is attached to the diffuser