Installing DPM

DPM allowable Outdoor and indoor unit models
DPM allowable Outdoor and indoor unit models
Outdoor unit models
AC071HCADKH
 Installation of multiple indoor units should consist of units that have the same capacity.
Space requirements for indoor and outdoor units and piping installation
(Refer to page 8~9 installation specification.)
- Two indoor units should be installed in one area which is not divided by a wall.
- The distance between two indoor units should be within a straight-line of 10m.
- After branching, the distance between the piping connected to the two indoor units
should be within 1m.
- The height difference between two units should be within 0.5m.
- Use the joint KIT that is only for DPM. (Please refer to the table below)
DPM KIT
18
2 indoor units connection
Indoor unit
AC035HBMDKH
2-Indoor unit connection
MXJ-2D2509K