Download Print this page

Side By Side Installation; Warming Drawer - Monogram ZEK7000SHSS Installation

Advertisement

MONOGRAM 27" BUILT-IN SINGLE OVEN
ZET1FHSS
INSTALLATION WITH
ADVANTIUM AND

WARMING DRAWER

21"
(53.3)
21"
A
(53.3)
2"
(5.1) min
2 1/2"
(6.4) min
2 1/2"
(6.4) min
2"
(5.1) min
2"
(5.1) min
2"
9 1/4"
(5.1) min
(23.5)
9 1/4"
B
(23.5)
STANDARD INSTALLATION
SIDE VIEW
STANDARD INSTALLATION
STANDARD INSTALLATION
SIDE VIEW
SIDE VIEW
UNDER COOKTOP INSTALLATION
H
C
GAS
L
31 1/4"
(79.4)
31 1/4"
27 5/8"
(79.4)
(70.2)
27 5/8"
(70.2)
3/4" thick platform
required
3/4" thick platform
required
STANDARD INSTALLATION
SIDE VIEW
STANDARD INSTALLATION
SIDE VIEW
For more details, refer to the installation instructions for this product on Monogram.com.
Dimensions in parentheses are in centimeters unless otherwise noted.
ZEK7000SHSS
ZEK7000SHSS

SIDE BY SIDE INSTALLATION

I
ELEC.
GAS
Wall oven
ELEC.
Wall oven
2 7/8"
(7.4) max
2 7/8"
Junction box
can protrude
(7.4) max
from back wall
Junction box
of installation
can protrude
(Not cabinet wall)
from back wall
of installation
(Not cabinet wall)
D
2"
2"
(5.1) min
ELEC.
ELEC.
SIDE BY SIDE INSTALLATION
FRONT VIEW OF CUTOUTS
SIDE BY SIDE INSTALLATION
FRONT VIEW OF CUTOUTS
C L
J
C L
E
ELEC.
wall oven
ELEC.
wall oven
FRONT VIEW
FRONT VIEW
ZEK7000SHSS
NOTES
A Dimensions per Advantium
(5.1) min
or Microwave Oven
requirements
B Dimension per Warming
ELEC.
Drawer requirements
ELEC.
C Note this oven is only
approved to be installed
under specific models as
labeled on this unit.
D Support platform made
of 3/4" (1.9 cm) wood is
required. Must be capable
of supporting 220 lbs (99
kg). Support Platform base
to be same height as toe
kick.
E Junction box location
for wall oven. (May also
be located in adjacent
cabinet).
F Gas regulator and electric
connections for cooktops
must be located in an
adjacent accessible location
to the right
G Top and/or side fillers
may be necessary if unit
is positioned between
existing cabinets. Be sure
they are attached securely,
since they will anchor the
oven in the cabinet.
H For flush oven installations,
the cooktop cutout must
GAS
be set back 2 1/2" (6.4 cm)
GAS
plus the cleat setback.
K
I Dimension varies
based on model.
example:
ELEC.
ZGU384 4 5/16"
cooktop
ELEC.
cooktop
F
J Dimension varies
based on model.
example:
J
ZGU384 12 1/16"
K Dimension varies
based on model.
example:
ZGU384 5"
L From the top surface of
the countertop to the top
surface of the wall oven
support platform
Product Specification Revised 9/16
(11.0 cm)
(from wall)
(30.6 cm)
(centerline)
(12.7 cm)

Advertisement