To Learn More - Panasonic CU-QZ9SKE Operating Instructions Manual

Hide thumbs Also See for CU-QZ9SKE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

To learn more...

Operation mode
HEAT
: Unit takes a while to warm up. The power indicator blinks during this operation.
• Unit may stops warm air supply for deice. The deice indicator ON during this operation.
COOL
: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.
DRY
: Unit operates at low fan speed to give a gentle cooling operation.
FAN
: To circulate air in the room.
AUTO
: During operation mode selection the power indicator blinks.
• Unit selects operation mode every 10 minutes according to temperature setting and room temperature.
ECONAVI
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
COOL/DRY
Set
temperature
HEAT
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
COOL
HEAT
+8/15°C
HEAT
10
00_ACXF55-03350_YZ0616-1.indb 10
00_ACXF55-03350_YZ0616-1.indb 10
-1 °C
Indoor
DBT
WBT
Max.
32
23
Min.
16
11
Max.
30
-
Min.
16
-
Max.
15
-
Min.
8
-
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
+1 °C
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
-1 °C
Outdoor
DBT
WBT
43
26
-15
11
24
18
-20
-
-
-
-20
-
6/28/2016 11:04:02 AM
6/28/2016 11:04:02 AM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-qz9skeCu-nz9skeCu-nz12skeCs-nz12skeCs-nz9ske

Table of Contents