Single-Frame 460V Heat Recovery Units - LG Multi IV Engineering Manual

Table of Contents

Advertisement

Table 16: Single-Frame 460V Heat Recovery Units.
Combination Unit Model Number
Individual Component Model Numbers
Cooling Performance
Nominal Cooling Capacity (Btu/h)
Rated Cooling Capacity (Btu/h)
Heating Performance
Nominal Heating Capacity (Btu/h)
Rated Heating Capacity (Btu/h)
Operating Range
Cooling (°F DB)
3
Heating (°F WB)
Synchronous — Cooling Based (°F DB)
Synchronous — Heating Based (°F DB)
Compressor
Inverter Quantity
Oil/Type
Fan (Top Discharge)
Type
Motor Output (kW) x Qty.
Motor/Drive
Cooling
Operating Range
(RPM)
Heating
Maximum Air Volume (CFM)
Unit Data
Refrigerant Type
Refrigerant Control/Location
Min. to Max. Number Indoor Units/
System
4
Sound Pressure dB(A)
5
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cables
6,7
Heat Exchanger
Material and Fin Coating
Rows/Fins per inch
Piping
8
Liquid Line Connection (in., OD)
Low Pressure Vapor Line Conn (in., OD)
High Pressure Vapor Line Conn (in, OD)
Factory Charge lbs. of R410A
1
Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft.
of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All
capacities are net with a Combination Ratio between 95–105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF
wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
2
Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9°F to +122°F and is achieved only
3
when all indoor units are operating in cooling mode. Does not impact synchronous operating range.
The System Combination Ratio must be between 50–130%.
4
6.0 Ton
ARUB072DTE4
-
72,000
1
2
69,000
1
81,000
77,000
2
14 to 122
-13 to +61
14 to 81
14 to 61
HSS DC Scroll x 1
PVE/FVC68D
Propeller (BLDC)
0.75 x 1
0 - 850
80 - 850
7,400
R410A
EEV/Indoor Unit
1 - 13
58.5
430
452
2 x 18
3/14
3/8 Braze
3/4 Braze
5/8 Braze
16.9
©
8.0 Ton
10.0 Ton
ARUB096DTE4
ARUB121DTE4
-
-
96,000
120,000
92,000
114,000
108,000
135,000
103,000
129,000
14 to 122
14 to 122
-13 to +61
-13 to +61
14 to 81
14 to 81
14 to 61
14 to 61
HSS DC Scroll x 1
HSS DC Scroll x 1
PVE/FVC68D
PVE/FVC68D
Propeller (BLDC)
Propeller (BLDC)
0.60 x 2
0.60 x 2
Brushless Digitally Controlled/Direct
0 - 1,050
0 - 1,050
80 - 1,050
80 - 1,050
9,850
9,850
R410A
R410A
EEV/Indoor Unit
EEV/Indoor Unit
1 - 16
1 - 20
59.0
59.0
540
540
573
573
2 x 18
2 x 18
Copper Tube/Aluminum Fin and GoldFin™/Hydrophilic
3/14
3/14
3/8 Braze
1/2 Braze
7/8 Braze
1-1/8 Braze
3/4 Braze
3/4 Braze
23.6
23.6
5
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
All communication cable to be minimum 18 AWG, 2-conductor, stranded, shielded, and must comply
6
with applicable local and national codes. Ensure the communication cable is properly grounded at the
master unit only. Do not ground the ODU-IDU communication cable at any other point.
Power wiring cable is field provided and must comply with the applicable local and national codes. See
7
page 34 for detailed electrical data.
Refer to the Refrigerant Piping section of this manual for correct line sizing. Contractor must use LG
8
manufactured Y-Branch and Header Kits only. Designer must verify refrigerant piping design configura-
tion using LG's computerized refrigerant piping (LATS Multi V) software to validate the pipe design.
GENERAL DATA
12.0
14.0
ARUB144DTE4
ARUB168DTE4
-
144,000
168,000
138,000
160,000
162,000
189,000
154,000
180,000
14 to 122
14 to 122
-13 to +61
-13 to +61
14 to 81
14 to 81
14 to 61
14 to 61
HSS DC Scroll x 2
HSS DC Scroll x 2
PVE/FVC68D
PVE/FVC68D
Propeller (BLDC)
Propeller (BLDC)
0.60 x 2
0.60 x 2
0 - 1,100
0 - 1,100
80 - 1,100
80 - 1,100
10,200
10,200
R410A
R410A
EEV/Indoor Unit
EEV/Indoor Unit
1 - 24
1 - 29
59.5
59.5
628
628
661
661
2 x 18
2 x 18
3/14
3/14
1/2 Braze
5/8 Braze
1-1/8 Braze
1-1/8 Braze
7/8 Braze
7/8 Braze
23.6
23.6
PRODUCT DATA | 25
-