Download Print this page

Servicing And Maintenance - Intertek Vent-Axia Svara Instructions Manual

Multifunctional app controlled fan

Advertisement

For the user

Servicing and maintenance

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE
ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE.
Strong solvents should not be used on the fan.
The fan must not be dipped in or sprayed with
water. For the fan to operate correctly it must be
cleaned at least twice a year, more often if
necessary.
– Before cleaning, switch off the power to the fan
(Figure U).
– Loosen the motor unit by grasping it (Figure V),
prise off the motor unit by leaveraging the cap
with your knuckles. Ensure that you have the
motor unit in a secure grip so you do not drop it
when it loosens.
0
0
1
1
U.
10
– Clean opening, the duct and the motor unit
with a damp cloth (if necessary, use a mild
detergent).
– The impellor does not detach and should be
wiped clean in its position on the motor housing
– If the fan has an external backdraft shutter the
shutter should be cleaned gently.
– Replace the motor unit in the frame.
Eco
Discarded fans should be submitted as electronic
waste to the recycling centre.
V.
Operating and installation instructions
The Vent-Axia Guarantee
Applicable only to products installed and used
in the United Kingdom. For details of guarantee
outside the United Kingdom contact your local
supplier.
Vent-Axia guarantees its Lo-Carbon products for
five years from date of purchase against faulty
material or workmanship. In the event of any part
being found to be defective, the product will be
repaired, or at the Company's option replaced,
without charge, provided that the product:
• Has been installed and used in accordance
with the instructions given with each unit.
• Has not been connected to an unsuitable elec-
tricity supply. (The correct electricity supply
voltage is shown on the product rating label
attached to the unit).
• Has not been subjected to misuse, neglect or
damage.
• Has not been modified or repaired by any
person not authorised by the company.
IF CLAIMING UNDER TERMS OF GUARANTEE
Please return the complete product to your
original supplier. The guarantee is offered to
you as an extra benefit, and does not affect your
legal rights.
Operating and installation instructions
For the user
Safe Water Installation
This product conforms to industry regulations for
electrical safety.
Supplier guarantees the functioning of the relevant
regulations and instructions are complied with.
All the holes for the screws to be carried out ac-
cording to the figures X and Y.
X.
For Wallcoverings Wooden (Figure V), drill only
through the coating and waterproofing.
NOTE: Never drill through any plywood.
Fill the entire hole with age-resistant sealing com-
pound. Use plumbing screws, screw through the
plywood into the regulatory framework.
Y.