  • Page 1 Manuale per l’installazione e l’uso Installation and operation manual 46216.212C Telecamera Bullet IR IP 3 Mpx, obiettivo 2,8-12 mm, PoE IP IR Bullet camera, 3 Mpx, 2.8-12 mm lens, PoE...
  • Page 2 Avvertenze - Prima di utilizzare il prodotto si raccomanda vivamente di leggere il manuale e di conservarlo in un luogo sicuro per consulta- zione futura. - Utilizzare l'alimentazione specificata per il collegamento. - Evitare di azionare il prodotto in modo improprio, sottoporlo a urti o vibrazioni, forti pressioni che possono danneggiarlo. - Non utilizzare detergenti corrosivi per pulire il corpo principale della telecamera.
  • Page 3: Installazione

    1) MIC: collegare al microfono 2) DC12V: collegare all’alimentazione 3) LAN: porta di rete (alcuni modelli supportano l’alimentazione PoE) - Regolazione della messa a fuoco Alimentazione Switch Modem Internet Messa a fuoco: Zoom: Fase 1: Rimuovere il parasole e la scatola dell’obiettivo dal dispositivo come mostrato sopra. Fase 2: Allentare le viti dell’obiettivo per la messa a fuoco.
  • Page 4 2.2 Interfacce e connessioni: per telecamera con ingressi e uscite allarme, RS485 scheda TF - Connessioni alle porte esterne: Manuale per l’installazione e l’uso Installation and operation manual Cavo di rete 46226.212 Telecamera Dome IR IP full HD, obiettivo 2,8-12 mm Camera Dome IR IP full HD, Lens 2,8-12 mm Router Cavo di...
  • Page 5 Allarme Sensore Alm_GND RS485+ RS485- 3 Installazione 3.1 Collegare la telecamera IP alla rete La connessione della telecamera IP è illustrata di seguito: Alimentazione Switch Modem Internet Alm_COM Alm_NO Alm_IN Allarme Sensore Alm_GND RS485+ RS485- Tastiera Per collegare il PC e la telecamera IP fare riferimento alla figura sopra. Prima di eseguire il collegamento, collegare i dispositivi esterni, quindi collegare l’alimentazione.
  • Page 6 4 Specifiche Articolo 46216.212C Sensore di immagine 1/3” CMOS Pixel immagine 2048x1536 Otturatore elettronico 1/25s ~ 1/100000s Diaframma automatico Diaframma fisso Telecamera Illuminazione minima 0 Lux (con LED IR attivo) Obiettivo 2,8-12 mm Tipo di attacco Attacco Φ14 Compressione H.264/MJPEG Risoluzione: 3 MP (2048x1536), 1080P (1920×1080), 720P (1280×720), D1, CIF, 480×240 Frame rate: 60Hz:30fps, 50Hz:25fps...
  • Page 7 Cautions - Before operation, we strongly advise users to read this manual and keep it properly for using later. - Please use the specified power supply to connect. - Avoid from in correct operation, shock vibration, heavy pressing which can cause damage to product. - Do not use corrosive detergent to clean main body of the camera. If necessary, please use soft dry cloth to wipe dirt; for hard contamination, use neutral detergent.
  • Page 8: Installation

    1) MIC: connect to MIC 2) DC12V: connect to power supply 3) LAN: network port (some models support PoE power supply) - Focus Adjustment Alimentazione Switch Modem Internet Focus Zoom: Step 1: Remove the sun shade and lens case from the device as shown above. Alimentazione Step 2: Loosen the screws of the lens for focusing. Then rotate the lens left or right to adjust the focus.
  • Page 9 2.2 Interfaces and Connections: for camera with connection of alarm infant, RS485 TF card - Connections of the external ports: Manuale per l’installazione e l’uso Installation and operation manual Network cables 46226.212 Telecamera Dome IR IP full HD, obiettivo 2,8-12 mm Camera Dome IR IP full HD, Lens 2,8-12 mm Router Network...
  • Page 10: Connect Ip-Camera To Network

    Alm_IN Allarme Sensore Alm_GND RS485+ RS485- Installation 3.1 Connect IP-CAMERA to Network The connection of IP-CAM is shown below: Power supply Alimentazione Switch Modem Internet Alm_COM Alm_NO Alm_IN Sensor Alarm Allarme Sensore Alm_GND RS485+ RS485- Keyboard Tastiera User can connect the PC and IP-CAMERA in accordance with the above picture. Before connecting, please connect external devices, and then connect the power.
  • Page 11: Specification

    4. Specification Article 46216.212C Image sensor 1/3” CMOS Image pixels 2048x1536 Electronic shutter 1/25 s ~ 1/100000 s Auto iris Fixed iris Camera Min. illumination 0 lux (IR LED ON) Lens 2.8-12 mm Mount type Φ14 mount Compression H.264/MJPEG Resolution: 3 MP (2048x1536), 1080P (1920×1080), 720P (1280×720), D1, CIF, 480×240 Frame rate: 60 Hz:30 fps, 50 Hz:25 fps Bit rate:...
  • Page 12 Vimar SpA: Viale Vicenza, 14 36063 Marostica VI - Italy Tel. +39 0424 488 600 - Fax (Italia) 0424 488 188 49400991A0 00 16 01 Fax (Export) 0424 488 709 VIMAR - Marostica - Italy www.vimar.com...