Mako Output Description - AVT Mako G-032B Technical Manual

Gige vision cameras
Table of Contents

Advertisement

Camera interfaces

Mako output description

Mako block diagram
Figure 30: Mako output block diagram
Caution
• Maximum 20 mA per output
• Camera Out Power  30 V may damage the camera
Camera Out Power
Resistor value*
5 V
1.0 k
12 V
2.4 k
24 V
4.7 k
* Resistor required if Out1/2/3 connected to a device with < 5 mA draw,
i.e. high impedance
Figure 31: Mako: Camera Out Power and external resistor
Internal
External
Camera Out Power
Out1
R
Out2
R
Out3
R
at  5 mA minimum required
current draw
Mako Technical Manual V2.1.0