6
NX-148E-RF LCD Touchpad with Receiver
Installation Instructions
Light control for X10 (46)
To control up to ten X10 devices from each touchpad (when used
with an X10 device such as an NX-507E, NX-508E, NX-534E or
NX-540E), do the following:
1.
Enter * 46. The display prompts you to Select Light Number
0-9.
2.
Enter the X10 device number you want to control.
3.
Press
or
to turn the selected device on or off.
4.
Repeat steps 2 and 3 until all devices have been
programmed.
5.
To exit, press #.
Unit and house codes for X10 (47)
To program the specific X10 unit and house codes for the X10
devices for this touchpad (when used with an X10 output device
such as an NX-507E, NX-508E, NX-534E or NX-540E), do the
following:
1.
Enter * 47.
2.
Enter your program code.
Note:
Use * key to select light number.
3.
Enter the X10 unit number (see Table 5) and press *.
Table 5.
X10 module numbers and unit numbers
X10 Module
1
2
3
number
Unit number
0
1
2
4.
Enter the X10 house code (see Table 6) and press *.
Table 6.
X10 house codes
0 = A
4 = E
1 = B
5 = F
2 = C
6 = G
3 = D
7 = H
5.
To exit, press #.
Change languages (49)
This function allows you to toggle between the two languages
programmed in your touchpad. To change languages, do the
following:
1.
Enter * 49. The touchpad toggles to the second language.
2.
Enter * 49. The touchpad toggles to the first language.
3.
To exit, press #.
Change user codes (5)
For partitioned systems, to change the user code of another
person you must have access to all or more partitions than the
user being changed. To change the user code, do the following:
1.
Enter * 5.
2.
Enter your master code.
3.
Enter the user number you want to change.
4.
Enter the new user code.
5.
To exit, press #.
4
5
6
7
8
9
10 11 12 13 14 15 16
3
4
5
6
7
8
9
10 11 12 13 14 15
8 = I
12 = M
9 = J
13 = N
10 = K
14 = O
11 = L
15 = P
Assign user authority (6)
To assign user authority levels, you must have authority over the
the assigned partitions. To assign user authority, do the
following:
1.
Enter * 6.
2.
Enter your master code.
3.
Enter the user number.
4.
Use keys 1 (yes) and 0 (no) to assign authorities when
prompted, or press * to move to the next prompt.
5.
Assign the partitions for the user.
6.
To return to step 3 and program another user code, press *.
7.
To exit, press #.
Note:
Retain at least one code with access rights to all partitions
to allow adding future users.
Reset function (7)
The system must be disarmed to reset the smoke detectors, zone
troubles, and zone tampers. To reset, do the following:
1.
Enter * 7.
2.
To exit, press #.
Note:
If the keypad begins beeping, the reset didn't execute
properly. Enter your code to silence the touchpad. Wait a
few minutes and repeat the reset.
Log review (90)
The control panel has an event log of at least the last 185 events
along with the date, time, and partition where the event occurred.
To review the log, do the following:
1.
Enter * 90.
2.
Enter your program or master code.
3.
Press
to view events from newest to oldest, or press
to view events from oldest to newest.
4.
To exit, press #.
The following screen sample shows an opening in Partition 3 on
September 25th at 5:57 pm by user 75. The * indicates that this
event is not programmed to be reported to the central monitoring
station.
Open
9/25
17:57
Table 10 on page 9 lists some of the possible event log messages.
Adjust view/brightness of LCD (91)
To adjust the view and brightness of the LCD display, do the
following:
1.
Enter * 91.
2.
Enter your master code.
3.
Press
or
to raise or lower the view angle and press * to
save the selection.
4.
Press
or
to brighten or dim the LCD and press * to save
the selection.
5.
To exit, press #.