ECTIVE CSI30 Installation And Operating Instructions Manual page 62

Csi-series;ssi-serie models with charger and mppt-charge controller
Table of Contents

Advertisement

Available languages

Available languages

Self error correction
Symptom
• inverter switched on
• status LED does not
flash
• no acoustic signal
• no output voltage
Acoustic signal
sounds once
acoustic signal sounds
2x and red LED flashes
2x every 8 sec .
60
[
ECTIVE
SINUS/SINE INVERTER – CSI-/SSI-SERIES
®
Possible reason
No input voltage .
blown fuse due to polarity
reversal
(Caution: polarity re-
versal can damage the
inverter despite a fuse)
1 . connection to
consumers cut off
2 . short circuit of
consumers
possible undervoltage
(see table)
Solution
1 . check battery voltage
2 . check input fuse
3 . check all connections to
battery
Exchange blown fuses and
connect cables correctly .
If inverter does not work
after exchange, it's broken .
Please call the support!
1 . check connection
2 . check if short circuit
1 . check charging status
of battery, charge if
necessary
2 . check compatibility
of battery cable, use
higher cross section if
necessary
3 . check if conductive
parts (cables, pole termi-
nals, lugs) are damaged
]

Advertisement