Organs Of Control And Indication; Front Instrumentation Panel - Nortec UL10 Operation Manual

0 – 40v / 0 – 40a charger / discharger
Table of Contents

Advertisement

CHARGER / DISCAHRGER UL10

2 Organs of control and indication

Organs of control, indication and connection of the UL 10 device for testing batteries are easily ac-
cessible from the front panel. Connections of specifically requested cells for automatic registration of
voltages of batteries, such as aircraft batteries and batteries for torpedoes or connections of several
PCs to the mains, are arranged on the rear face.

2.1 Front instrumentation panel

1)
The POWER ON / OFF switch with a LED indicator
а)
triggers the device on and off
b)
The red LED indicates that the device is connected to the mains
2)
The automatic protection circuit 16 А protects 220 V AC power supply.
The indicator
The LC graphic display (2 lines, 40 characters) serves to transmit information to the user and to in-
dicate the parameters of operation of programs in the progress of charging.
2)
The touch-input keyboard
The keys BREAK, CLEAR, PRINT, ENTER↵ serve to interrupt programs, to delete erroneously en-
tered data, to print out results and to confirm input of requested data, respectively.
The digital unit enables the user to enter digital data, such as parameters of batteries and the opera-
tor number.
The key * ensures access to the information about the system menu.
3)
The printer
The built-in printer for printing out protocols can be enabled at any moment before and after opera-
tions with a battery. It prints out all basic parameters of a battery and all errors, if necessary.
6)
The battery tester
The battery tester is connected to the UL10 device with a plug-and-socket connector type VG 95
328 C10-6SN (6-contact). The battery tester enables to measure voltages of batteries between
-4.0 to + 4.0 V.
7)
Mains connection to the battery
The battery is connected via special connecting cables to the UL 10 device with two 4-pin Plug and
socket connectors type VG complying with requirements VG 95 234.
8)
The manufacturer/ designation of the UL 10 device
8
OPERATION MAUNAL
© NorTec Electronics 2014