4 Ratings

4.1 Input & Output Parameters
input voltage
input frequency
input power
external mains protection
fan power
charge current range
discharge current range
charge voltage range
discharge voltage range
voltage error
current power error
temperature error
Insulation
Protection type
working temperature
Weight
Dimensions
Free space for exhaust

4.2 Working temperature range

The device operation is guaranteed within the temperature range -20 С to + 45 С.
The accuracy of the readings of the indicator and printed out discharge and charge parameters
correspond to the above indicated.
The accuracy of output values within the temperature range -20
2 years since the time of delivery of the device.
12
220 V + 10% (single-phase alternating)
45-60 Hz
2000 VА
16 А, mean inertia
about 100 / 300 l/min
0.5 – 40 А
0.5 – 40 А
0.1 – 40 V
0.1 – 40 V
< 0.1 % of rated parameter plus ±5 discharge
< 3 % of rated parameter plus ±5 discharge
< ±2 С
VDE 0160, class 1
IP 54
-20 С to +45 С
about 50 kg (in 19" body, without battery cable)
width 400 mm, height 504 mm, depth 242 mm
> 50 mm
С to +45
о
OPERATION MAUNAL
С is guaranteed for
О
© NorTec Electronics 2014