Program 430. Maintenance - Enclosed Aircraft Nickel-Cadmium Battery Type Saft - Nortec UL10 Operation Manual

0 – 40v / 0 – 40a charger / discharger
Table of Contents

Advertisement

CHARGER / DISCAHRGER UL10
7.23 Program 430. Maintenance – enclosed aircraft nickel-cadmium battery
type SAFT
Program number
Operation number
Operation type
Battery type
Manufacturing process
Access to valves
Battery type
Minimum battery capacity
Maximum battery capacity
Minimum battery voltage
Maximum battery voltage
Maximum number of batteries
Stage 1 (S1)
Stage 1 (S1)
Stage 2 (S2)
Stage 2 (S2)
Stage 4 (S4)
Stage 4 (S4)
Stage 4 (S4)
60
Stage name
I-Charge 1
I-Charge 1
Topping charge 1
Topping charge 1
Break
Discharge
Discharge
Discharge
Current = xС (A)
Umax = V/battery
Current = xС (A)
Measurement of
voltages of individual
batteries
Discharge current
а = xС (A)
Discharge depth
V/battery
Measurement of
voltages of individual
batteries
OPERATION MAUNAL
Maximum
duration
430
4
Maintenance
Nickel-cadmium
Fused electrodes
open, type SAFT
30
4 Ah
50 Ah
1.2 V
31.2 V
26
х = 1
75 min.
1.57
75 min.
х = 0.1
240 min.
Sound signal 225 min.
30 min
х = 1
54 min.
1
54 min.
Sound signal 54 min.
© NorTec Electronics 2014

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents