Program 410. Maintenance - Air-Tight Aircraft Lead Acid Battery - Nortec UL10 Operation Manual

0 – 40v / 0 – 40a charger / discharger
Table of Contents

Advertisement

CHARGER / DISCAHRGER UL10
7.18 Program 410. Maintenance – air-tight aircraft lead acid battery
Program number
Operation number
Operation type
Battery type
Manufacturing process
Access to valves
Battery type
Minimum battery capacity
Maximum battery capacity
Minimum battery voltage
Maximum battery voltage
Maximum number of batteries
Stage 1 (S1)
Stage 1 (S1)
Stage 2 (S2)
Stage 2 (S2)
Stage 3 (S3)
Stage 3 (S3)
Stage 4 (S4)
Stage 4 (S4)
Stage 4 (S4)
Stage 5 (S5)
Stage 5 (S5)
Stage 6 (S6)
Stage 6 (S6)
Stage 7 (S7)
Stage 7 (S7)
Stage 7 (S7)
Note: the program is identical to program 310
Note: when the maximum output current of the device is exceeded the maximum time para-
meters change accordingly.
54
Stage name
Discharge
Discharge
Precharge
Precharge
I-Charge 1
I-Charge 1
U-Charge 1
U-Charge 1
U-Charge 1
Discharge
Discharge
I-Charge 2
I-Charge 2
U-Charge 2
U-Charge 2
U-Charge 2
Discharge current
а = xС (A)
Discharge depth
V/battery
Voltage chargingа
Umax = V/battery
Current = xС (A)
Current = xС (A)
Umax = V/battery
Umax = V/battery
I а= xС (A)
Umax = V/battery
Discharge current
а = xС (A)
Discharge depth
V/battery
Current = xС (A)
Umax = V/battery
Umax = V/battery
I а= xС (A)
Umax = V/battery
OPERATION MAUNAL
Maximum
Duration
410
4
Maintenance
Lead acid
Gel / absorbed
electrolyte
Unavailable
10
2 Ah
200 Ah
2
30
15
0.2
6 h
1.5
6 h
2.4
2 h
Х=0.4
2 h
0.4
6 h
2.4
6 h
2.4
6 h
0.02
6 h
2.4
2 h
0.2
6 h
1.5
6 h
0.4
6 h
2.4
6 h
2.4
6 h
0.02
6 h
2.4
2 h
© NorTec Electronics 2014