The joints can be specified with the parameters illustrated below:
• Any combination other than CORNER = "ROUND" and JOINT =
"ROUND" may take long time for plotting.
• Lines not jointed (which are not drawn with one stroke) are excluded.
• If the attributes of lines (line color, line width, line type) change,
treatment for joints may not be performed.
• The outermost line of the plot may not be treated for joints.
■PEN ADJUST (mm) / PEN ADJUST (in)
Allows for setting of the pen width adjust value. Plots can be produced
with a pen width larger or smaller than the pen width preset with the data
or on the panel by the adjust value in the range of the maximum pen width
16 mm (0.63 inches) and minimum width 1 dot.
This setting is performed on the third hierarchy.
<Parameter (numerical value input method)>
-0.99 to +0.99 (-0.038 to +0.038 inches)
ROUND
Default value = 0
MITERED
MITERED length