Chapter 4 Remote Interface Reference
SCPI Conformance Information
Device Specific Commands
T h e f o l l o w i n g c o m m a n d s a r e d e v i c e - s p e c i f i c t o t h e A g i l e n t E 3 6 3 3 A a n d A g i l e n t
E 3 6 3 4 A p o w e r s u p p l i e s . T h e y a r e n o t i n c l u d e d i n t h e ' 1 9 9 6 . 0 ' v e r s i o n o f t h e
S C P I s t a n d a r d . H o w e v e r , t h e s e c o m m a n d s a r e d e s i g n e d w i t h t h e S C P I
s t a n d a r d i n m i n d a n d t h e y f o l l o w a l l o f t h e c o m m a n d s y n t a x r u l e s d e f i n e d b y
t h e s t a n d a r d .
Non-SCPI Commands
APPLy {<voltage>|DEF|MIN|MAX>}[,{<current>|DEF|MIN|MAX}]
APPLy?
CALibration
:COUNt?
:CURRent[:DATA] <numeric value>
:CURRent:LEVel {MIN|MID|MAX}
:CURRent:PROTection
:DAC:ERRor
:SECure:CODE <new code>
:SECure:STATe {OFF|ON},<code>
:SECure:STATe?
:STRing <quoted string>
:STRing?
:VOLTage[:DATA] <numeric value>
:VOLTage:LEVel {MIN|MID|MAX}
:VOLTage:PROTection
OUTPut
:RELay[:STATe] {OFF|ON}
:RELay[:STATE]?
SYSTem
:LOCal
:REMote
:RWLock