1

DESCRIPTION OF THE BOILER

1. 1
INTRODUCTION
"PLANET DEWY 90 A - 110 A" boilers are
premix condensation thermal appliances
which use microprocessor technology for
function control and management.
1.2
DIMENSIONS
240
210
450
1.3
TECHNICAL FEATURES
Heat output (80-60°C)
Nominal
kW (kcal/h) 24.5 (21,070)
Minimum
kW (kcal/h)
Heat output (50-30°C)
Nominal
kW (kcal/h) 26.9 (23, 1 30)
Minimum
kW (kcal/h)
D.H.W. heat output
Nominal
kW
Heat input
Nominal/Minimum (g.c.v.)
kW
Nominal/Minimum (n.c.v.)
kW
Efficiency (80-60°C)
Nominal/Minim. output (g.c.v.)
Nominal/Minim. output (n.c.v.)
Efficiency (50-30°C)
Nominal/Minim. output (g.c.v.)
Nominal/Minim. output (n.c.v.)
Water content
Adsorbed power consumption W
Electrical protection grade
Maximum water head
bar
Maximum temperature
Expansion vessel
Water content
Preloading pressure
bar
C.H. setting range
D.H.W. setting range
The gas consumptions refer to the calorific value at standard conditions at 15°C - 1013 mbar.
They comply with the european directives
90/396/CEE, 89/336/CEE, 73/23/CEE,
92/42/CEE and with the european specifi-
cation EN 483.
These appliances heat and supply domestic
hot water with a sealed forced draught
Z
S3
30
110
375
90 A
110 A
29.4 (25,280)
8.6 (7,400)
10.4 (9,000)
32.4 (27,860)
9.6 (8,250)
11.7 (10,060)
24.5
29.4
27.8/10.0
33.3/12.0
24.9/9.0
30.0/10.8
%
88.2/86.7
88.2/87.4
%
97.9/96.3
98.0/97. 1
%
97.0/96.5
97.3/97.4
% 107.7/107.2
108. 1 /108.2
l
4.8
5.3
175
175
IP X4D
IP X4D
3
3
°C
85
85
l
8
8
1
1
°C
20÷80
20÷80
°C
35÷60
35÷60
combustion chamber with electronic igni-
tion and control.
The instructions given in this manual are
provided to ensure proper installation and
perfect operation of the appliance.
405
R
M C.H. flow
G
E
U
S3 Condensation outlet
S3
180
Z mm
R M G E U
70 70 70 70
D.H.W. flow rate (EN 625) l/min
D.H.W. flow rate ∆t 30°C
l/min
D.H.W. flow rate ∆t 35°C
l/min
Minimum D.H.W. flow rate l/min
D.H.W. pressure
Minimum
bar
Maximum
bar
Smokes temperature
Maximum/Minimun (80-60°C) °C
Maximum/Minimum (50-30°C) °C
Smokes flow
kg/h
Category
Type
Weight
Main burner nozzles
Quantity
G20
ø mm
Gas consumption
Nominal/Minimum (G20)
m
3
/h
Gas supply pressure
G20
mbar
Pollutants in flue gas
CO
ppm
NOx
ppm
C.H. return
3/4"
3/4"
Gas connection
3/4"
D.H.W. inlet
1/2"
D.H.W. outlet
1/2"
ø 25
90 A
110 A
220
190
Fig. 1
90 A
110 A
10.5
13.7
11.5
14. 1
9.8
12. 1
2
2
0.5
0.5
7
7
65/64
70/69
46/43
48/45
42.4
49.0
II
II
2H3P
2H3P
C
C
13-33-43-53-83
13-33-43-53-83
kg
49
51.4
1
1
6.5
6.0
2.65/0.95
3. 1 7/1. 1 4
20
20
35
27
30
35
1

Advertisement