Hamworthy wessex modumax mk3 Instructions For Use

Hamworthy wessex modumax mk3 Instructions For Use

Advertisement

Quick Links

Note:- This boiler is for use only on Natural Gas (2nd
Family) I
or LPG Propane I
2H
person must carry out any adjustments.
WARNING: All installations MUST conform to the
relevant Gas Safety and Building Regulations. It is
law that all gas appliances are installed and
maintained by competent persons in accordance
with the above regulations. This appliance must
2
5
1
4
Figure 1 - Boiler Control Panel Fascia
The boiler display screen provides various levels of access to view and change the performance parameters of
the boiler.
The User can change parameters relating to time clock, boiler program timings and boiler temperature setpoint.
In addition, the User can view performance data and reset specific lockouts. Should a lockout occur, a code will
be displayed on the screen. A red LED is displayed constantly when a non-blocking fault is detected (following
correction of the fault, the LED goes off). The LED flashes when a blocking fault is detected (in this case, the
LED goes off after the fault has been corrected and the reset button on the interface
has been pressed),
Should a fault code appear which cannot be reset, or a fault code repeatedly occurs, contact Hamworthy
Heating for assistance. Do not continue to operate or use the boiler as this may cause damage to the con-
trols.
Hamworthy Heating Limited
WESSEX MODUMAX Mk3

INSTRUCTIONS FOR USE

. Only a competent
3P
9
7
6
8
Wessex Modumax mk3
only be used for the purpose and under the
conditions, for which it is designed.
The boiler condense outlet shall not be modified or
blocked.
Electrical supply to the boiler MUST be suitably
earthed.
Button
Symbol
Function
1
RESET
3
2
DHW
3
Selection of Heating Mode
Automatic (time control)
Continuous ' Normal' temperature
Continuous ' Reduced ' setback temperature
10
Standby - boiler off.
4
Rotary knob function control
5
ESC
6
OK
7
ON/OFF
8
INFO
9
Green LED (flame present)
10
Red LED (fault detected)
1
500001309-A

Advertisement

loading

Summary of Contents for Hamworthy wessex modumax mk3

  • Page 1: Instructions For Use

    Should a fault code appear which cannot be reset, or a fault code repeatedly occurs, contact Hamworthy Heating for assistance. Do not continue to operate or use the boiler as this may cause damage to the con- trols.
  • Page 2 If the problem persists, seek expert advice from your Press OK – Year will flash – Use rotary knob to enter installer or Hamworthy Heating Ltd. year required – Press OK to enter When finished press ESC to return to PROG screen –...
  • Page 3 99 Extension module 2, error 8 is essential that the boiler is serviced regularly. Con- 100 2 clock time masters 3 tact your installer or Hamworthy Heating Ltd. for ad- 102 Clock time master without backup 3 vice. 103 Communication error 8...
  • Page 4 349 146 Buffer storage tank return valve Y15 missing 3 Phone Number 01202 662500 350 146 Buffer storage tank address error 3 Fax Number 01202 665111 Service 01202 662555 Spares 01202 662525 Technical 01202 662527/662528 Hamworthy Heating Limited Wessex Modumax mk3 500001309-A...