B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 40 of 53)
ADDR
REGISTER NAME
B250
IEC 61850 GGIO2.CF.SPCSO17.ctlModel Value
B251
IEC 61850 GGIO2.CF.SPCSO18.ctlModel Value
B252
IEC 61850 GGIO2.CF.SPCSO19.ctlModel Value
B253
IEC 61850 GGIO2.CF.SPCSO20.ctlModel Value
B254
IEC 61850 GGIO2.CF.SPCSO21.ctlModel Value
B
B255
IEC 61850 GGIO2.CF.SPCSO22.ctlModel Value
B256
IEC 61850 GGIO2.CF.SPCSO23.ctlModel Value
B257
IEC 61850 GGIO2.CF.SPCSO24.ctlModel Value
B258
IEC 61850 GGIO2.CF.SPCSO25.ctlModel Value
B259
IEC 61850 GGIO2.CF.SPCSO26.ctlModel Value
B25A
IEC 61850 GGIO2.CF.SPCSO27.ctlModel Value
B25B
IEC 61850 GGIO2.CF.SPCSO28.ctlModel Value
B25C
IEC 61850 GGIO2.CF.SPCSO29.ctlModel Value
B25D
IEC 61850 GGIO2.CF.SPCSO30.ctlModel Value
B25E
IEC 61850 GGIO2.CF.SPCSO31.ctlModel Value
B25F
IEC 61850 GGIO2.CF.SPCSO32.ctlModel Value
B260
IEC 61850 GGIO2.CF.SPCSO33.ctlModel Value
B261
IEC 61850 GGIO2.CF.SPCSO34.ctlModel Value
B262
IEC 61850 GGIO2.CF.SPCSO35.ctlModel Value
B263
IEC 61850 GGIO2.CF.SPCSO36.ctlModel Value
B264
IEC 61850 GGIO2.CF.SPCSO37.ctlModel Value
B265
IEC 61850 GGIO2.CF.SPCSO38.ctlModel Value
B266
IEC 61850 GGIO2.CF.SPCSO39.ctlModel Value
B267
IEC 61850 GGIO2.CF.SPCSO40.ctlModel Value
B268
IEC 61850 GGIO2.CF.SPCSO41.ctlModel Value
B269
IEC 61850 GGIO2.CF.SPCSO42.ctlModel Value
B26A
IEC 61850 GGIO2.CF.SPCSO43.ctlModel Value
B26B
IEC 61850 GGIO2.CF.SPCSO44.ctlModel Value
B26C
IEC 61850 GGIO2.CF.SPCSO45.ctlModel Value
B26D
IEC 61850 GGIO2.CF.SPCSO46.ctlModel Value
B26E
IEC 61850 GGIO2.CF.SPCSO47.ctlModel Value
B26F
IEC 61850 GGIO2.CF.SPCSO48.ctlModel Value
B270
IEC 61850 GGIO2.CF.SPCSO49.ctlModel Value
B271
IEC 61850 GGIO2.CF.SPCSO50.ctlModel Value
B272
IEC 61850 GGIO2.CF.SPCSO51.ctlModel Value
B273
IEC 61850 GGIO2.CF.SPCSO52.ctlModel Value
B274
IEC 61850 GGIO2.CF.SPCSO53.ctlModel Value
B275
IEC 61850 GGIO2.CF.SPCSO54.ctlModel Value
B276
IEC 61850 GGIO2.CF.SPCSO55.ctlModel Value
B277
IEC 61850 GGIO2.CF.SPCSO56.ctlModel Value
B278
IEC 61850 GGIO2.CF.SPCSO57.ctlModel Value
B279
IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value
B27A
IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value
B27B
IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value
B27C
IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value
B27D
IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value
B27E
IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value
IEC 61850 Report Settings (Read/Write Setting) (14 modules)
B280
IEC 61850 Report Control 1 RptID
B2A1
IEC 61850 Report Control 1 OptFlds
B2A2
IEC 61850 Report Control 1 BufTm
B2A4
IEC 61850 Report Control 1 TrgOps
B2A5
IEC 61850 Report Control 1 IntgPd
B2A7
...Repeated for Report 2
B-48
RANGE
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
---
0 to 65535
0 to 4294967295
0 to 65535
0 to 4294967295
F60 Feeder Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F209
---
1
F001
---
1
F003
---
1
F001
---
1
F003
DEFAULT
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
0
0
GE Multilin