Procedure 2: Use Bios Recovery Dip Switch And Recovery.cap File - Cisco UCS C240 M4 Installation And Service Manual

Hide thumbs Also See for UCS C240 M4:
Table of Contents

Advertisement

Chapter 3
Maintaining the Server

Procedure 2: Use BIOS Recovery DIP switch and recovery.cap File

See
Step 1
Download the BIOS update package and extract it to a temporary location.
Copy the contents of the extracted recovery folder to the root directory of a USB thumb drive. The
Step 2
recovery folder contains the recovery.cap file that is required in this procedure.
Note
Step 3
Power off the server as described in
Step 4
Disconnect all power cords from the power supplies.
Step 5
Slide the server out the front of the rack far enough so that you can remove the top cover. You might have
to detach cables from the rear panel to provide clearance.
Caution
Remove the top cover as described in
Step 6
Slide the BIOS recovery DIP switch from position 1 to the closed position (see
Step 7
Reconnect AC power cords to the server. The server powers up to standby power mode.
Step 8
Insert the USB thumb drive that you prepared in
Step 9
Step 10
Return the server to main power mode by pressing the Power button on the front panel.
The server boots with the updated BIOS boot block. When the BIOS detects a valid recovery.cap file on
the USB thumb drive, it displays this message:
Found a valid recovery file...Transferring to Cisco IMC
System would flash the BIOS image now...
System would restart with recovered image after a few seconds...
Step 11
Wait for server to complete the BIOS update, and then remove the USB thumb drive from the server.
Note
After the server has fully booted, power off the server again and disconnect all power cords.
Step 12
Slide the BIOS recovery DIP switch from the closed position back to the default position 1.
Step 13
Note
Replace the top cover, replace the server in the rack, replace power cords and any other cables, and then
Step 14
power on the server by pressing the Power button.
OL-32474-01
Figure 3-34
for the location of the SW8 block of DIP switches.
The recovery.cap file must be in the root directory of the USB thumb drive. Do not rename this
file. The USB thumb drive must be formatted with either FAT16 or FAT32 file systems.
If you cannot safely view and access the component, remove the server from the rack.
During the BIOS update, Cisco IMC shuts down the server and the screen goes blank for about
10 minutes. Do not unplug the power cords during this update. Cisco IMC powers on the server
after the update is complete.
If you do not move the jumper, after recovery completion you see the prompt, "Please remove
the recovery jumper."
Shutting Down and Powering Off the Server, page
Removing and Replacing the Server Top Cover, page
Step 2
into a USB port on the server.
Cisco UCS C240 M4 Server Installation and Service Guide
Service DIP Switches
3-9.
3-10.
Figure
3-34).
3-73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents