Stereo Filter; Separation - 1; Separation - 2 - JVC HR-S9800U Service Manual

Hide thumbs Also See for HR-S9800U:
Table of Contents

Advertisement

(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
(5) Adjust with the channel buttons (+,–) on the VCR (or on
the remote controller) so that the frequency of the meas-
uring point (D1) becomes the specified value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
(7) Disconnect the short wire between the short point (D2)
and the GND (Ground).

3.5.3 Stereo filter

Signal
(A)
RF signal (Audio: No signal)
Mode
(B)
Tuner
EE
Equipment
(C)
Oscilloscope
Measuring point (D)
IC1501 pin 26
EVR mode
(F1)
Jig RCU : Code "57"
EVR address
(F2)
A : 22 (Press remote controller "2"
key twice.)
Specified value
(G)
Minimum level
Adjustment tool
(H)
Jig RCU [PTU94023B]
Digit-key remote controller
(1) Set an audio signal mode of the RF signal generator to
no signal.
(2) Connect the equipment (C) to the measuring point (D).
(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
(5) Adjust with the channel buttons (+,–) on the VCR (or on
the remote controller) so that the level of the measuring
point (D) becomes the specified value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)

3.5.4 Separation - 1

Signal
(A)
RF signal
(Audio: L-ch 300 Hz 14% modulated)
Mode
(B)
Tuner
EE
Equipment
(C)
Audio level meter
Measuring point (D)
IC1501 pin 26
EVR mode
(F1)
Jig RCU : Code "57"
EVR address
(F2)
A : 23 (Press remote controller "2"
and "3" keys.)
Specified value
(G)
Minimum level
Adjustment tool
(H)
Jig RCU [PTU94023B]
Digit-key remote controller
(1) Set an audio signal mode of the RF signal generator to
alternate L-ch 300 Hz 14% modulated.
(2) Connect the equipment (C) to the measuring point (D).
(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
3-6
(5) Adjust with the channel buttons (+,–) on the VCR (or on
the remote controller) so that the level of the measuring
point (D) becomes the specified value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)

3.5.5 Separation - 2

Signal
(A)
RF signal
(Audio: L-ch 5 kHz 14% modulated)
Mode
(B)
Tuner
EE
Equipment
(C)
Audio level meter
Measuring point (D)
IC1501 pin 26
EVR mode
(F1)
Jig RCU : Code "57"
EVR address
(F2)
A : 24 (Press remote controller "2"
and "4" keys.)
Specified value
(G)
Minimum level
Adjustment tool
(H)
Jig RCU [PTU94023B]
Digit-key remote controller
(1) Set an audio signal mode of the RF signal generator to
alternate L-ch 5 kHz 14% modulated.
(2) Connect the equipment (C) to the measuring point (D).
(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
(5) Adjust with the channel buttons (+,–) on the VCR (or on
the remote controller) so that the level of the measuring
point(D) becomes the specified value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
3.5.6 SAP VCO
Signal
(A)
No. signal
Mode
(B)
Tuner
EE
Equipment
(C)
Frequency counter
Measuring point (D1)
IC1501 pin 26
Short point
(D2)
C1505 (–) terminal
EVR mode
(F1)
Jig RCU : Code "57"
EVR address
(F2)
A : 25 (Press remote controller "2"
and "5" keys.)
Specified value
(G)
78.67 ± 0.5 kHz
Adjustment tool
(H)
Jig RCU [PTU94023B]
Digit-key remote controller
(1) Connect the short wire between the short point (D2) and
the GND (Ground).
(2) Connect the equipment (C) to the measuring point (D1).
(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
(5) Adjust with the channel buttons (+,–) on the VCR (or on
the remote controller) so that the frequency of the meas-
uring point (D1) becomes the specified value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
(7) Disconnect the short wire between the short point (D2)
and the GND (Ground).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents