Marantz PM-KI-PEARL /N1B/U1B Service Manual page 9

Table of Contents

Advertisement

To check if the amp is in order, switch off the unit and switch
it on again one minute later. This action will deactivate
the protection operation. If the PROT-1 (pin54) remains
"L", which constitutes an abnormality, the unit shuts down
approximately 2 seconds later and the OPERATION indicator
starts flickering.
If the protection operation will not be deactivated after the
power is turned on again, the amp circuit may be broken.
[B] The PROT-2 (pin53) is the port to detect
abnormalities of the power supply circuit
1. Detection of an abnormality in the power amp power
supply circuit.
This port monitors the midpoint voltage of the power amp
power supply between +50V and -50V. If the voltage at
the connection point of R829 and R830 exceeds DC
±1.2V, Q823 or Q824 will turn on to change the signal
from the PROT-2 (pin53) to L from H.
2. Detection of an abnormality in the preamp power supply
circuit.
This port monitors the midpoint voltage between +30V
and -30V. If the voltage at the connection point of R823
and R824 exceeds DC ±1.2V, Q821 or Q822 will turn on to
change the signal from the PROT-2 (pin53) to L from H
3. Detection of an abnormality in the function relay power
supply circuit.
If the +24V of the relay power supply receives an electric
current of over 120mA, Q831 and Q834 will turn on to
change the signal from the PORT-2 (pin53) to L from
H.
4. The Fuse (F851) inside blows, the signal from the PROT-2
(pin53) terminal will be changed to L from H.
If any of the above four abnormalities is detected, the signal
from the POW-1 (pin25) changing to L from H, the power
relay L852 will be turned off and the unit will be shut down.
Then, the OPERATE indicator flickers and indicates that an
abnormality has occurred.
When the OPERATE LED enters the state of blinking eight
times a second, it doesn't return to the normally state.
Because, when the power supply is turned on again, it is
dangerous.
Return to normally operation.
1. Turn off POWER ON/OFF button.
2. One minute after, POWER ON/OFF buttom is turned on
while pushing at the same time as DISPLAY button with
ATT button.
3. The model name and the version are displayed on the
display.
4. Then, turn off POWER ON/OFF buttom. Next, it starts
with the factory shipped when turning on power.
[B] PROT-2 (pin53) は、 電源回路の異常を検出するポー ト
1. パワーアンプ用電源回路の異常を検出。
パワーアンプ用電源の +50V と-50V の中点電圧を監視し、
R829とR830 の接続点の電圧が約 ±1.2V (DC) を超え
ると、 Q823 もしくは Q824が ONして PROT-2 (pin53)が
"H → L" になる。
2. プ リ アンプ用電源回路の異常を検出。
プリ アンプ用電源の +30V と -30V の中点電圧を監視し、
R823とR824 の接続点の電圧が約 ±1.2V (DC) を超え
ると、 Q821 もしくは Q822が ONして PROT-2 (pin53)が
"H → L" になる。
3. フ ァンクシ ョ ン リ レー用電源回路の異常を検出。
リ レー用電源の +24V に約 120mA を超える電流が流れる
と、 Q831, Q834が ONしてPROT-2(pin53)が "H → L" に
なる。
4. F851 FUSEが切れている場合、 Q835が ONし、 PROT-2
(pin53) が "H → L" になる。
1. ∼ 4. のいずれかの異 常を検 出すると、 POW-1 (pin25) を
"H→L" にして、 電源 リ レー L852 をOFFしシ ャ ッ トダウンします。
このときOPERATEインジケーターが点滅 (1秒間に約8回) し、
異常が起きたことを表示します。
これは、アンプ回 路もしくは電 源 回 路の故 障を想 定した
PROTECTION 動作で、 危険回避のため即座に電源を切る動
作です。
OPERATE インジケーターが 1 秒間に約 8 回の速い点滅状態
になると、 電源が再投入できないようになり ます。
これは、 電源を再投入することによる危険を回避するためメモ
リ ーに書き込まれるためです。
電源を投入できるようにするためには、 メモ リ ーク リ アの処理を
行ってく ださい。
メモ リ ーク リ アの手順
1. まず、 電源をOFF にしてく ださい。
2. 1 分ほど待ってから、 本体の DISPLAYボタンとATTボタン
を押しながらPOWER ON/OFF SWを押し電源を投入しま
す。これでサービスモー ドに入り ます。
3. ディ スプレーにモデル名とバージ ョ ンが表示されます。
4. POWER ON/OFF SWを押して電源を切ると、 メモ リ ーがク
リ アされます。この操作で電源が投入できるようになり ます
が、 この操作をすると全ての設定がク リ アされ出荷状態に戻
り ますのでご注意く ださい。