Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge the high voltage
capacitor before servicing, unless testing requires power.
Illustration
Touch Pad/Control
FTP Connector
Panel
TOP
Model MMV5207A**
1
2
3
4
5
6
7
8
9
10
11
12
13
30
!
Component
Test Procedure
Removal of Touch
Pad/Control Panel is
required to perform test.
Check for continuity.
When touched: Less than
400
When not touched: More
than 1 mega
16023056 Rev. 0
W ARNING
Custom Program
Auto Defrost
Time Defrost
Rapid Defrost
Power Level
Cook Time
Hold/Warm
Stop/Clear
Enter/Start
Control Setup
Add 30 Seconds
Light Hi/Lo/Off
Light Timer
Kitchen Timer
Vent On/Off
Vent 5-Speed
Vent Auto Time Set
Results
Pad
Trace
1
8 & 1
2
8 & 2
3
8 & 3
4
8 & 4
5
8 & 5
6
8 & 6
7
8 & 7
8
13 & 5
9
13 & 6
0
13 & 7
Popcorn
11 & 1
Soften
10 & 6
Melt
10 & 7
Cook
11 & 2
Reheat
11 & 3
Poultry
10 & 4
9 & 3
More
12 & 6
Less
12 & 7
11 & 4
11 & 6
11 & 7
13 & 1
9 & 2
12 & 2
13 & 3
13 & 4
12 & 1
11 & 5
Clock
12 & 5
10 & 3
9 & 5
12 & 4
10 & 1
10 & 2
10 & 5
©2004 Maytag Services
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents