Graco PT2500 Instructions Manual page 20

1/4 gallon per minute, 230 vac, 50 hz
Table of Contents

Advertisement

23. Lubricate the screws (25) and then install and torque
them to 19–23 N.m .
CAUTION
Whenever you remove the paint pump screws,
torque them as instructed above, and then retorque
them after 3 to 5 hours of operation.
Torque to 14–17 N.m.
Apply sealant to the threads.
Lubricate the internal threads.
Torque to 14–17 N.m.
Torque to 32–34 N.m.
Lubricate the threads.
Torque to 36–41 N.m.
Torque to 19–23 N.m.
Do not alter the position of the nut.
The start switch is located
in the switch box.
66
35
Fig. 15
Service
38
37
36
3
67
20
28a
28
28b
28e
28c
28f
28d
24. Check the hydraulic oil level and add Graco-ap-
proved oil as necessary until the level is 25 mm from
the top of the plate. See Fig. 11, page 14.
25. Turn the pressure control fully
(no pressure). Plug in the sprayer and turn it on. Run
the sprayer for two minutes to fill the hydraulic sys-
tem. Increase the pressure to maximum and turn the
sprayer on and off four times to help rid the hydraulic
system of air.
4
4a
26a
26
counterclockwise
18a
C
21
22a
22b
24
25
27