Troubleshooting Schedule - Husqvarna 115iHD45 Operator's Manual

Hide thumbs Also See for 115iHD45:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Troubleshooting schedule

Keypad
Troubleshooting takes place from the keypad.
Keypad
Warning indicator flashing.
No. 3 in figure (5).
The machine does not start
Warning indicator lit.
No. 3 in figure (5).
Troubleshooting the battery and/or the battery charger during charging.
Battery
LED display
Warning indicator flashing.
No. 2 in figure (27).
Warning indicator lit.
No. 2 in figure (27).
Battery charger
LED display
Error LED flashing
Red LED on
MAINTENANCE
Possible faults
Overload.
Temperature deviation.
The power trigger and the activate
button are pressed at the same time.
Service
Possible faults
Temperature deviation.
Over voltage.
Under voltage
Cell difference too much (1V).
Possible faults
Temperature deviation.
Cell difference too much (1V).
Possible action
The cutting attachment is jamed.
Release the cutting attachment.
Allow the machine to cool down.
Release the power trigger and the
machine is active.
Contact your service agent.
Possible action
Use the battery in surroundings
where temperatures are between -10
°C and 40 °C.
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the battery
charger.
Charge the battery.
Contact your service agent.
Possible action
Use the battery charger only when the
surrounding temperature is between 5
°C and 40 °C.
Contact your service agent.
English – 17