RM5310 – RM5385
It must be possible to shut off the refrigerator from the gas line separately by
means of a shut-off device. The shut-off device must be easily accessible.
➤ Connect the refrigerator to the gas supply securely and without any
voltage according to fig. c, page 10.
The following applies for Europe: Use a cutting ring fitting in accordance
with EN 1949.
A hose connection is not permitted.
➤ Have a leak test and a flame test performed in accordance with EN 1949
by an authorised specialist.
Ensure you are issued with a certificate of inspection.
9.2
Connecting to 12 Vg and 230 Vw
A
NOTICE!
The electrical installation and repairs may only be performed
by a specialist in accordance with the applicable regulations
and standards.
According to EN 1648-1, the respective negative and positive
cables of the DC connections for heating and lighting may
not be joined with one another in a caravan. This can cause
electrical interference or damage to electrical components.
The inverter may only be connected by a specialist.
I
NOTE
The mains socket must be easily accessible so that you can
unplug the power cord if required, thereby disconnecting the
refrigerator from the power.
The plug of the AC connection cable must not be cut off.
The connection cables must be laid so that they do not come
in contact with hot parts of the unit/burner or with sharp edges.
Changes to the internal electrical installation or the connection
of other electrical components (e.g. extra third party fans) to
the internal wiring of the refrigerator will void the E1/CE
approval and any claims from the guarantee and product
liability.
EN
Connecting the refrigerator
25