Gas Specifications
- Australia
Main Burner Injectors
Pilot Burner Injectors
Pilot Screw Adjustment
Burner Operating Pressure (*)
Supply Pressure
- New Zealand:
Main Burner Injectors
Pilot Burner Injectors
Pilot Screw Adjustment
Burner Operating Pressure (*)
Supply Pressure
- UK Only:
Category:
Flue Type:
Main Burner Injectors
Pilot Burner Injectors
Pilot Screw Adjustment
Burner Operating Pressure (*)
Supply Pressure
NOTE:
*
Measure burner operating pressure at Operating Pressure Test Point (Lower - Out) on gas
control valve with both burners operating at 'High Flame' setting. Refer to 'Gas Conversion
and Specification' Section for further details.
Gas Conversion and Specifications
Natural Gas
Ø 3.10mm
0.62
Full Out (CCW)
0.98 kPa
1.13 - 2.0 kPa
Natural Gas
Ø 3.10mm
0.62
Full Out (CCW)
0.98 kPa
1.13 - 2.0 kPa
II
(20, 37).
2H3P
A
1.
Natural Gas (G20)
Ø 3.10mm
0.45
Full Out (CCW)
0.98 kPa
20 mbar
33
LP Gas (Propane)
Ø 1.90mm
0.35
1½ turns out (CCW)
2.50 kPa
2.75 - 3.0 kPa
LP Gas
Ø 1.90mm
0.35
1½ turns out (CCW)
2.50 kPa
2.75 - 3.0 kPa
Propane (G31)
Ø 1.90mm
0.30
1½ turns out (CCW)
2.50 kPa
37 mbar