Flexpoint 1250-D Specifications - Alpha FP1208-F-5A Technical Manual

Flexpoint 1208-f/1232-d/1250-d series indoor ups
Table of Contents

Advertisement

4.0
Specifications
4.3 Flexpoint 1250-D specifications
Models
FP1250-D-8A:
FP1250-D-8B:
FP1250-D-8C:
FP1250-D-8D:
FP1250-D-8E:
FP1250-D-8-6C:
FP1250-D-8-F:
Input
AC Input Voltage:
AC Input Frequency:
Connection:
Surge Protection:
Output
Operational Output Power (ONT Load):
Output Voltage:
Connections:
Mechanical Dimensions
Unit Dimensions for 5, 7.2 or 8Ah
Battery L x W x D (in/mm):
Unit Weight without Battery (lb/kg):
5.1Ah Battery Weight (lb/kg):
7.2Ah Battery Weight (lb/kg):
8.0Ah Battery Weight (lb/kg):
Estimated Battery Runtimes
5.1Ah Battery (Hrs):
7.2Ah Battery (Hrs):
8.0Ah Battery (Hrs):
Battery Type:
Visual Indicators
AC Power:
Battery:
Replace Battery:
Mute
Audible Status Indicators
Loss of Input Power:
Low Battery:
Replace Battery:
Push Buttons
DC Start:
Silence Alarm:
18
Power Line Cords
120Vac 3-Conductor NEMA 5-15 power cord (875-698-19)
230Vac 3-Conductor Schuko input power cord (876-042-19)
230Vac 3-Conductor United Kingdom input power cord (876-046-19)
240Vac 3-Conductor Australia/New Zealand input power cord (876-043-19)
250Vac 3-Conductor Brazilian 14136 input power cord (876-044-19)
120Vac 3-Conductor NEMA 5-15 power cord with BC cable (875-698-19)
230Vac 3-Conductor India input power cord (876-045-19)
90Vac–264Vac
50/60Hz
IEC 320-C6 3-Prong with cable ties to prevent accidental removal of the line cord.
Standards
Telcordia GR-1089
ANSI/IEEE C62.41
IEC 61000-4-5
50W max. continuous, up to 9W continuous on F connector
12Vdc nominal
7-position connector and F-type coaxial connector
36W Load
0.9
1.4
1.7
Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)
Green LED on: AC power present and powering the ONT
Green LED on: Battery powering ONT during AC loss
Green Flashing: Battery powering ONT during AC loss and running low
Red LED off: Battery present and working correctly
Red LED on: Replace battery / battery missing
Green LED on: Lit when Silence Alarm button is pressed.
Single, one second chirp
Single chirp every 15 seconds
Double chirp every 15 minutes
Press for at least 1 second when unit is off to start up on battery without AC present
When any audible alarm is on, press this button for at least 1 second and release to silence the audible alarm
until power is cycled.
Level
1.2x50us combination wave at 2kV
6.6 x 7.5 x 3.2 / 167.6 x 190.5 x 81.3
1.4 / 0.64
3.9 / 1.8
5.7 / 2.6
5.73 / 2.6
50W Load
0.7
1.0
1.1
010-353-B9-001 Rev. A1 (09/2015)