Dis-
Const.
played
fault
code
48
4C
50
X
51
X
58
X
59
X
A7
106
Weath.-
System char-
comp.
acteristics
X
Mixer closes
X
Mixer closes
X
No DHW heat-
ing
X
No DHW heat-
ing
X
No DHW heat-
ing
X
No DHW heat-
ing
X
Control mode
as per deliv-
ered condition
Cause
Measures
Lead break,
Check flow temper-
flow tempera-
ature sensor (see
ture sensor,
page 131)
heating circuit
2 (with mixer)
Lead break,
Check flow temper-
flow tempera-
ature sensor (see
ture sensor,
page 131)
heating circuit
3 (with mixer)
Short circuit,
Check sensors
cylinder tem-
(see page 122)
perature sen-
sor
Short circuit,
Check sensor (see
outlet temper-
page 122)
ature sensor
Lead break,
Check sensors
cylinder tem-
(see page 122)
perature sen-
sor
Lead break,
Check sensor (see
outlet temper-
page 122)
ature sensor
Programming
Replace program-
unit faulty
ming unit