OPERATION
Initial Lighting: When lit for the first time, the appliance emits a slight odor. This is normal
temporary condition caused by the "burn-in" of internal paints and lubricants used in the
manufacturing process and does not occur again. Simply run the main burner on high for
approximately one half hour.
Leak testing: This must be done before initial use, annually, and whenever any gas
components are replaced or serviced. Do not smoke while performing this test, and remove
all sources of ignition. See Leak Testing Diagram for areas to check. Turn all burner
controls to the off position. Turn gas supply valve on. Brush a half-and-half solution of liquid
soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with
one recommended by your dealer and have the appliance inspected by a certified gas
installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have
the applicant inspected by a certified gas installer or dealer. Do not use the appliance until
the leak have been corrected.