AX-100/200TFR series
Frequently Asked Questions (FAQ's)

Q-15: How long can AX-TFRs constitute a linear protection?

A-15:AX-100TFRs can protect long distance without limitation. Please choose
channel settings as suggested in a diagram below. It is important to set
apart adjacent beam channels from next to each other to secure reliability.

Q-16: Can I arrange AX-TFRs in a stack?

A-16: Yes, Double stacked protection is possible.
<Configuration example for a double stacking protection>
Important notes:
> Between two separate zones, please make sure that beams with the same
channel do not overlap in the same direction unless receivers are away 10X
the distance of 100/200 feet [30m/60m] from beam transmitters (1000 feet
[300m] for AX-100TFR, 2000 feet [600m] for AX-200TFR)
[For more detailed information, please refer to the instruction manual P.8:
SETTING]
P.8
All rights reserved by OPTEX Co., Ltd.