Q-03: Is AX-TFR compromised in performance because it's low-energy
consuming?
A-03: Although the power consumption is lower, its performance is more
than before; retaining same beam blocking ratio tolerance with new features
added. AX-TFRs withstand 99% attenuated photobeams without
malfunctioning.
<Basic Performance>
・ 99% Beam blocking stability
・ 4 selectable beam frequencies
・ D.Q. circuit (Environmental disqualification)
・ N.C./N.O. output selection switch
・ A.G.C. circuit
[For more information, please refer to P.1: FEATURES of the AX-TFR
instruction manual]
Q-04: What is the power-range (VDC) required to run AX-TFR?
A-04: AX-TFRs are designed to run with current between 2.5 VDC~4.3 VDC
Q-05: Why do I have to use SAFT 's LSH20 (3.6 VDC) instead of ordinary
CR123A (3.0 VDC)?
A-05: Ordinary CR123A (3.0 VDC) does not have enough capacity for
running an AX-TFR for a longtime. To run an AX-TFR, thirty-two CR123A cells
are necessary whereas, LSH20 guarantees 3 years of operation just with four
cells. LSH20, despite its uniqueness, it is widely available and its reliable
performance is often used in various military forces worldwide.
Temperature Range: -60 ~ 85 degree C
LSH20
(3.6VDC、13.0Ah)
[For more information about the SAFT battery, please refer to a website:
http://www.saftbatteries.com/]
<LSH20>
High Heat Durability: 120 degree C
Battery Life: 10 years
AX-100/200TFR series
Frequently Asked Questions (FAQ's)
・ International protection IP55
・ Beam interruption adjustment function
・ High grade spherical lens
・ Easy angle adjustment function
CR123A
(3.0VDC、1.6Ah)
All rights reserved by OPTEX Co., Ltd.