Mitsubishi SRC92ZL-S Technical Manual & Parts List page 59

Inverter wall mounted type residential air-conditioner
Table of Contents

Advertisement

Trouble of outdoor unit
(1)
(2)
(3)
Outdoor fan motor error
the fan motor and outdoor
ourdoor PCB
Power supply reset
Is it normalized?
Malfunction by temporary noise
Insufficient refregerant amount, Faulty power transistor, Broken compressor wire
Service valve close, Defective EEV, Defective outdoor PCB
outdoor
Replace fan motor. (If the
error persists after replacing
the fan motor, replace the
outdoor PCB.)
57
-
-
(1)
Notes (1)
(2)
(3)
Check coil resistance, see page 55.
Defective fan motor, connector poor
connection, defective outdoor PCB
Replace outdoor fan motor
See pages 62 for the fan motor and outdoor PCB check pro-
After making sure the fan motor and outdoor PCB are nor-
'09•SRK-DB-087D
'12 • SRK-T-130
62
60