Maintenance

Lubrication

The Idler arm bearing (Fig. 7) must be lubricated after
every 8 hours of operation with a No. 2 Lithium based
grease.
Figure 7
The overrunning clutch pulley (Fig. 7) must be lubricated
after every 8 hours of operation with a No. 2 Lithium based
grease.
The (2) fan shaft bearings (Fig. 7 & 8) must be lubricated
after every 8 hours of operation with a No. 2 Lithium based
grease.
Figure 8
Under normal conditions, grease the (2) castor wheels and
(2) wheel pivot tubes (Fig. 8) after every 50 hours of use.
Use a No. 2 Lithium based grease.
The (2) mount frame pivots (Fig. 9) must be lubricated
after every 8 hours of operation with a No. 2 Lithium based
grease.
Under normal conditions, grease the (2) drive shaft fittings
(Fig. 10) after every 100 hours of use and guards after
every 8 hours of operation. Use a No. 2 Lithium based
grease.
Figure 10
11