Summary of Contents for Hayward ISSC100AU

  • Page 1 P/N: ISSC100AU Owners manual 2 Wheel & 4 Wheel Suction-Side Poolcleaners Hayward Pool Products (Australia) Pty Ltd. Melbourne-Sydney-Brisbane-Perth Email: sales@hayward-pool.com.au Website: www.hayward-pool.com.au P.O Box 4384, Dandenong South, VIC, 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2...
  • Page 2 FEATURES SELF ADJUSTING TURBINE VANES All the cleaners have the patented self-adjusting turbines, which maximize the power from the water flow. This turbine is similar to a paddle wheel with blades that are adjustable. This feature allows the cleaner to still move at low suction and low pressure.
  • Page 3: Installing The Cleaner

    PARTS 2 wheel model 4 wheel model Installing the Cleaner STEP 1 ; preparing your pool. 1. Manually remove very large and excessive debris from pool ( ie. post storm, spring cleaning/pool opening situations). 2. Perform a backwash, clean your filter, skimmer baskets and pump basket.
  • Page 4 STEP 2 ; connecting the hoses. 0.5m - 0.63m STEP 2 STEP 2 Connecting the hoses . . . ™ in Step 3. (We have already done this step for you). 2. Connect all the hoses (except the Leader Hose). Connect male to female.
  • Page 5 STEP 4 ; submerging the cleaner. Lower the cleaner into the water. While your pump is running, take the end of the hose with the Adjustable Regulator Valve (if you need it) and hold it against one of the return fittings to expunge all of the air in the hose and the cleaner.
  • Page 6: Adjusting The Bypass Valve

    STEP 6 ; adjusting the cleaner. ADJUSTING WHEEL RPM: For the cleaner to run optimally the revolutions per minute(RPMs) should be between 14 (Note it will still clean as low as RPM but will NOT climb walls). While the cleaner is running take it by the leader hose so that the cleaner is just below the water.
  • Page 7 Servicing the Cleaner Removal of Obstructions Turbine Vanes/Blades The turbine vanes have to be placed in the turbine hub a larger oval certain direction. We use the following mnemonic the turbine vanes are like “a wave breaking” toward the front of the clean- round er.
  • Page 8 Wheel or Bearing Removal & Replacement CLICK When the unit is reassembled turn the right front wheel (looking from behind) and make sure everything turns smoothly. Skirt and Inlet Removal & Replacement Inlet Sizes: Small* Medium Large small pump/variable speed average pump large pump low flow...
  • Page 9: Troubleshooting

    Troubleshooting ; ALWAYS TURN OFF THE SYSTEM BEFORE PERFORMING ANY REPAIRS. Problem Solution Cleaner doesn’t move or moves too slow. • Check wheel RPM. • Obstruction in the cleaner itself. If there was an obstruction make sure vanes are replaced correctly. •...
  • Page 10 Hayward Pool Products Limited Warranty - Australia and New Zealand...