Download Print this page

Hitachi NR 83A Instruction Manual And Safety Instructions page 15

Advertisement

Available languages

Available languages

I _ ...
English
Maintenance chart
ACTION WHY H OW
Drain air line filter daily. Prevent accumulation of moisture Open manual petcock.
and dirt.
Keep lubricator filled. Keep the Nailer lubricated. Fill with Hitachi pneumatic tool
lubricant.
Clean filter element - then blow Prevent clogging of filter with dirt. Follow manufacturer's instructions.
air through filter in direction
opposite to normal flow.
Clean magazine and feeder Prevent a jam. Blow clean daily.
mechanism.
Keep push lever working properly. Promote operator safety and Blow clean daily.
efficient Nailer operation.
Lubricate the Nailer after nailing. Extend the Naiier life. Supply 2 - 3 drops of lubricant
into the Nailer.
Drain air compressor. Keep the Nailer operated properly. Open petcock on air compressor tank.
Operator troubleshooting
Most minor problems can be resolved quick[y and easily using the table below.
If problems persist, contact a Hitachi authorized service center for assistance.
PROBLEM CHECK METHOD CORRECT[ON
Nailer operates, but no nail is driven. Check for a jam. Clear a jam.
Check function of nail feeder per Clean and lubricate.
page 14.
Ribbon spring weakend or damaged? Replace ribbon spring.
Check for proper nails. Use oniy recommended nails.
Weak drive. Check air pressure.
Slow to cycle. Increase air pressure. (DO not
exceed 120 psi (8.3 bar 8.5 kgflcm2))
Use Hitachi pneumatic tool lubricant
Driver blade worn?
Piston O-ring worm or damaged? Contact Hitachi for replacement.
Drives too deep. Check air pressure. Reduce air pressure. (Adjust 70 - 1 20 psi)
Skipping nails. Intermittent feed. Check for proper nails. Use only recommended nails.
Check function of nail feeder per Clean and lubricate.
page 14.
Ribbon spring weakend or damaged? Replace ribbon spring.
Use Hitachi pneumatic tool lubricant
Piston O-ring cut or heavily worm? Contact Hitachi for replacement
Naijs jam. Driven nail is bent. Check for proper nails. Use only recommended nails.
Driver blade worm? Contact Hitachi for replacement.
Drives properly during norma[
operation, but does not drive fully Check inside diameter of air hose.
at faster nailing speeds. Use larger air hose.
- 15 -

Advertisement

loading

This manual is also suitable for: