en | System Setup – first Steps
5
System Setup – first Steps
5.1

Introduction

The DIVAR IP 6000 systems are based on Windows Storage Server 2012 R2 operating system.
Windows Storage Server 2012 R2 systems provide a user interface for initial server
configuration, unified storage appliance management, simplified setup and storage
management, and support for Microsoft iSCSI Software Target.
It is specially tuned to provide optimal performance for network-attached storage. Windows
Storage Server 2012 R2 operating system provides significant enhancements in storage
management scenarios, as well as integration of storage appliance management components
and functionality.
This chapter is valid for DIVAR IP 6000 2U models that come with pre-installed hard drives.
The operating system of empty units loaded with third party hard drives will start normally,
but the added hard drives must be configured with the RAID utility prior to initial software
setup.
For further information, refer to the RAID setup chapter in the Installation manual.
See also
5.2

Setup instruction

By default the virtual network adapter (the two physical NIC ports are teamed by default) is
configured to obtain a valid network address from a DHCP server in the local network. If there
is no DHCP server in the network, the system will use the following network settings:
5.3

Setting the IP address

The default IP address can be changed using:
Notice!
Changing the network settings using the IP Helper tool is only possible If the default system
password is still unchanged.
Notice!
We strongly recommend that you change the password of the administrative BVRAdmin user
account after setting the IP address.
Microsoft Utility Server Manager program
To change the IP address using Microsoft Utility Server Manager program:
4
2016.03 | V2 | DOC
Additional software and documentation, page 22
IP address: 192.168.0.200
Subnet mask: 255.255.255.0
User: BVRAdmin
Password: WSS4Bosch
Microsoft Utility Server Manager program
or
IP Helper tool
Open the Microsoft Utility Server Manager and follow the instructions on the screen to
configure the network interface cards (NICs).